background image

MODEL

5300

Premier Series

Universal Auto Changeover 

Up to 3 Heat / 2 Cool Heat Pump or 

2 Heat / 2 Cool Conventional Thermostat

USER

MANUAL

READ ALL INSTRUCTIONS

BEFORE PROCEEDING

Braeburn Systems LLC, as an Energy Star 
partner has determined that this product 
meets the Energy Star Guidelines developed 
by the U.S. Environmental Protection Agency 
& the U.S. Department of Energy for 
maximum energy efficiency.

CONTENTS

1
2

QUICK REFERENCE
PROGRAMMING 

USER SETTINGS

QUICK REFERENCE

1

3
4

ADDITIONAL OPERATION FEATURES
TROUBLESHOOTING

  SYSTEM Button:  

Selects AUTO (Heat/Cool), COOL, OFF, 

  HEAT or EMER.

  PROG Button:

  Press to enter the program setup mode where 

  you can select the time, temperature and fan setting for each 
  program period. Scrolls backward between user/installer 
  setup screens. 

  HOLD Button:  

Enables or disables extended hold mode or 

  temporary program override.

  RETURN Button:  

Press and hold for 4 seconds to enter the 

  user settings mode (see user manual). Scrolls between user/
  installer setup screens. Returns unit to normal mode when 
  in program mode.

  DAY/TIME Button:  

Enters time and day setting mode. 

  Selects individual days in program mode.

  FAN Button:  

Selects AUTO, ON, CIRC (recirculate) and 

  PROG (program) modes.

  RESET Button: 

Resets time, program and some user settings back to the factory default. See section 4 for a list of functions

  that will return to their factory default settings after the RESET button is pressed.

     Button:  

Turns on backlight for 10 seconds.

       Button:

  Increases setting (time, temperature, etc.). Scrolls between option settings.

      Button:

  Decreases setting (time, temperature, etc.). Scrolls between option settings.

 

1

1

2

3

4

5

6

7

9

10

model 5300 shown with cover open

8

9

7

1

6

2

3

4

5

10

8

2

3

+

        Press and hold both buttons at the same time to view the outdoor temperature if an outdoor sensor is connected.

Содержание Premier 5300

Страница 1: ...isables extended hold mode or temporary program override RETURN Button Press and hold for 4 seconds to enter the user settings mode see user manual Scrolls between user installer setup screens Returns unit to normal mode when in program mode DAY TIME Button Enters time and day setting mode Selects individual days in program mode FAN Button Selects AUTO ON CIRC recirculate and PROG program modes RE...

Страница 2: ... mode M AM SET 2 2 PROGRAMMING USER SETTINGS 2 3 Setting Thermostat System Selection The system can be selected by pressing the System button There are five possible settings to select from AUTO COOL OFF HEAT and EMER AUTO Auto can only be selected if it was enabled by the installer see Section 4 of the Installer Guide If AUTO is selected the system cycles between heating and cooling as determined...

Страница 3: ...ton again and the LCD display will show d3 SET X where X equals the F C differential setting This is the current third stage differential setting 6 Press the or button to set the third stage differential to your desired setting of 1 2 3 4 5 or 6 F 0 5 1 0 1 5 2 0 2 5 or 3 0 C 4 2 PROGRAMMING USER SETTINGS cont 5 2 4 2 Setting the Filter Check Monitor see also section 3 7 The default setting is 0 d...

Страница 4: ... where X is the temporary override limits 18 Press the or button to change the Temporary Override Time Limit to the desired value of 4 3 2 or 1 hour 2 4 8 Setting the Multi Level Keypad Lockout Code see section 3 10 19 Press and hold the RETURN button for four seconds Press RETURN button repeatedly until 000 SET LOCK is displayed 20 Press the or button to enter a 3 digit code using the RETURN butt...

Страница 5: ...mming mode was selected during the Installer Setup Installer Guide the default program is the 2 events per day shown in the chart above Weekday Weekend MORN DAY EVE NIGHT Time 6 00 pm Heat 70 F 21 C Cool 75 F 24 C Time 8 00 am Heat 62 F 17 C Cool 83 F 28 C Time 6 00 am Heat 70 F 21 C Cool 75 F 24 C Time 10 00 pm Heat 62 F 17 C Cool 78 F 26 C 4 Event Time 6 00 pm Heat 70 F 21 C Cool 75 F 24 C Time ...

Страница 6: ...le in auto changeover mode When you place the system in the HEAT or COOL modes of operation an appropriate indicator will appear in the LCD display when the system is running When you place the system in the OFF mode the display will indicate OFF NOTE If the PROG button is pressed while AUTO is selected the thermostat will switch from the AUTO mode to the mode currently in the display NOTE If Auto...

Страница 7: ...utomatically 2 PROGRAMMING USER SETTINGS Entering Your Program 7 DAY Commercial Mode 1 Press the PROG button to enter the Program setting mode Press the SYSTEM button to select HEAT to set heating times and temperatures OCC occupied set point of the Whole Week will be displayed The display will show M TU W TH F SA SU to indicate the whole week is being programmed The hour portion of the set point ...

Страница 8: ...r portion of the set point time and the AM PM indicator will be flashing 6 Follow steps 3 through 5 to set the set point times temperatures and fan mode for the periods of DAY EVE and NIGHT 2 PROGRAMMING USER SETTINGS cont 15 Entering Your Program 5 2 DAY Residential Mode continued 7 After pressing the PROG button you will enter the Weekend Program Group The display will show SA SU to indicate the...

Страница 9: ...stat If installed at setup the display temperature is either the temperature at the sensor or an average of the temperature at the sensor and the temperature at the thermostat 17 cont 3 ADDITIONAL OPERATION FEATURES 3 4 Remote Outdoor Sensor if installed The Braeburn Remote Outdoor Sensor is used for determining if balance points have been exceeded and for outdoor temperature display It is not use...

Страница 10: ...in the display See instructions provided with your UV source for recommendations on interval setting When the selected interval has been reached and required replacement has been performed press the RETURN button in any normal mode to reset the timer and turn off the warning 19 3 ADDITIONAL OPERATION FEATURES cont 3 9 Humidifier Pad Monitor see section 2 4 4 for setting The Humidifier Pad Monitor ...

Страница 11: ... used The proper operation of this function is preprogrammed into this thermostat No user changes are necessary 20 3 ADDITIONAL OPERATION FEATURES cont 3 11 Adaptive Recovery Mode ARM In order to maximize comfort and energy efficiency this thermostat is equipped with Adaptive Recovery Mode ARM This feature minimizes the amount of time required by the heating or cooling system to reach the new set ...

Страница 12: ...m from short cycling This thermostat automatically provides a delay see section 4 of the Installer Guide after turning off the system output to protect the compressor This protection is also present in the heat mode of operation on single stage heat pump systems to protect the compressor If enabled during Installer Setup see section 4 of the Installer Guide this thermostat also provides cold weath...

Страница 13: ...n or not often enough Potential Solution Increase or decrease first stage temperature differential setting as appropriate to provide the desired performance level see section 2 4 25 4 TROUBLESHOOTING cont Symptom Thermostat will not follow program set points Potential Solutions Check current time of day day of week program settings Verify AM PM indicator is accurately displaying desired time setti...

Страница 14: ...display will return to the normal mode If an incorrect code is entered the display will flash no Symptom Keypad does not function Potential Solution Keypad is locked check for LOCK segment in display 27 4 TROUBLESHOOTING cont Symptom LO is shown in the thermostat display where the room temperature is normally displayed Potential Solutions The temperature sensed by the thermostat is lower than the ...

Страница 15: ...aeburn Systems LLC agrees to repair or replace at its option any Braeburn thermostat under warranty provided it is returned postage prepaid to our warranty facility in a padded carton within the warranty period with proof of the original date of purchase and a brief description of the malfunction This limited warranty does not include the cost of removal or re installation This warranty gives you ...

Отзывы: