background image

CONTENTS

WARNING!

Important Safety Information

FEATURES
SPECIFICATIONS
INSTALLATION

 

Replacing Existing Thermostat

 

Installing Your New Thermostat

TESTING YOUR NEW THERMOSTAT
PROGRAMMING

 

Default Thermostat Settings

 

Setting Current Time of Day and Day of Week

 

Setting Thermostat User Options

 

 

Setting Temperature Differentials

 

 

Setting Residual Cooling Fan Delay

 

 

Setting Extended Hold Time

 

 

Setting Filter Check Monitor

 

 

Setting Recirculating Fan Cycle

 

Setting Your Energy Saving Programs

 

 

Tips Before Starting

 

 

Programming Overview for 7 day Programming Mode

 

 

Entering Your 7 day Program

 

 

Programming Overview for weekday-weekend 

 

 

(5-2 day) Programming Mode

 

 

Entering your weekday-weekend (5-2 day) 

 

 

day Program

ADDITIONAL OPERATION FEATURES

 

Review Set Temperature

 

Temporary Program Override

 

Extended Hold (Vacation) Mode

 

Filter Check Monitor 

 

Keypad Lockout

 

Adaptive Recovery Mode 

 

Recirculating Fan Mode 

 

High Temperature Safety Switch

 

Compressor Protection

 

Changing Fahrenheit (˚F) to Celsius (˚C)

 

Low Battery Detection and Replacement

 

LED Status Indicator

 

Resetting the Thermostat 

TROUBLESHOOTING
WIRING DIAGRAMS

1

2

3

4
5

6

7
8

5.1

3.1
3.2

5.2
5.3

5.4

6.1
6.2
6.3
6.4
6.5
6.6
6.7
6.8
6.9

5.4

.1

5.4

.2

5.4

.3

5.4

.4

5.4

.5

•  Always turn off power to the air conditioning or heating system prior to installing, removing,  

 

  cleaning or servicing thermostat.

•  Read this manual thoroughly prior to installing, programming or operating this thermostat.

•  This thermostat is designed for use with a 24 Volt AC low voltage multi-stage heat / cool system.

• Do not use this thermostat on systems with voltages higher than 30 Volts AC.

•  This thermostat requires 24 Volt AC Power for normal operation and control of the heating or  

 

  cooling system.

•  The thermostat also requires two (2) properly installed "AA" alkaline batteries to retain clock

   settings in the event of loss of AC Power due to power outage or rolling blackouts.

•  Wiring must conform to all building codes and ordinances as required by local and national code   

  authorities having jurisdiction.

•  Do not short (or jumper) across terminals on the gas valve or at the heating or cooling system    

  control board to test the thermostat installation. This could damage the thermostat and void 

  the warranty.

•  Do not select COOL mode of operation if the outside temperature is below 50˚ F (10˚ C). This  

 

  could possibly damage the controlled cooling system and may cause personal injury.

•  This thermostat should only be used as described in this manual. Any other use is not  

 

  recommended and will void the warranty.

1

5.3

.1

5.3

.2

5.3

.3

5.3

.4

5.3

.5

6.10
6.11
6.12
6.13

Содержание Premier 5100

Страница 1: ...Store this booklet for future reference Braeburn Systems LLC as an Energy Star partner has determined that this product meets the Energy Star Guidelines developed by the U S Environmental Protection Agency the U S Department of Energy for maximum energy efficiency For more information on energy savings go to www energystar gov Premier Series Universal 7 Day or 5 2 Day Programmable 2 Heat 2 Cool He...

Страница 2: ...4 1 5 4 2 5 4 3 5 4 4 5 4 5 Always turn off power to the air conditioning or heating system prior to installing removing cleaning or servicing thermostat Read this manual thoroughly prior to installing programming or operating this thermostat This thermostat is designed for use with a 24 Volt AC low voltage multi stage heat cool system Do not use this thermostat on systems with voltages higher tha...

Страница 3: ... B C INSTALLATION 3 3 1 Replacing Existing Thermostat 1 Always turn off power to the air conditioning or heating system prior to removing existing thermostat 2 Remove the cover of your old thermostat and locate the wire terminals Do not remove wires from terminals yet 3 Using small pieces of masking tape label wires prior to removal from terminals Use the chart below to determine the new terminal ...

Страница 4: ...mostat rear body mounting plate against wall in the desired thermostat location 6 Guide thermostat wires through center hole in rear body Continue to hold rear body against wall 7 Mark placement of mounting holes as appropriate and drill using a 3 16 drill bit 8 Gently tap supplied plastic anchors into the holes in the wall 9 Place the thermostat rear body mounting plate against the wall in the de...

Страница 5: ...2 Restore system power so you can test installation NOTE Test your thermostat prior to programming any user settings Pressing the RESET button will erase any user entries for time of day day of week option settings and programming if previously programmed This will return all user settings and return them to their default values Remember this will erase all programs entered by the user 1 Place the...

Страница 6: ...n Delay 60 Seconds Filter Check Monitor 0 days off Recirculating Fan Timer Reset with 120 minute off cycle NOTE The thermostat will return to normal operating mode automatically after 15 seconds if no key is pressed It will also return to normal operating mode immediately if the RETURN button is pressed 1 When in normal operating mode press the DAY TIME keypad button The LCD display will be cleare...

Страница 7: ...ormal operating mode press and hold the RETURN button for 4 seconds The LCD display will show d1 x where x equals the F C differential setting This is the current first stage differential setting 5 3 1 Setting the First And Second Stage Differential Second Stage Differential First Stage Differential The default setting is 2 F 1 0 C This means that the room temperature must change 2 F 1 0 C in addi...

Страница 8: ...from indefinite LG to 24 hours SH 10 Press RETURN again to set the Filter Check Monitor or wait 15 seconds for the thermostat to return to the normal mode 5 3 4 5 3 5 Setting Filter Check Monitor see also section 6 4 Setting the Recirculating Fan Cycle see also section 6 7 The default setting is 0 days monitor disabled 11 After pressing the RETURN button again the display will show FILT XXX SET wh...

Страница 9: ... 78 F 26 C 5 4 3 Entering Your Program section 5 4 2 Programming Overview For 7 Day Programming Mode Programming switch set to 7 DAY see installation section You can select one of three Quick Program Groups or Individual Day programming to allow you to change the daily setpoint times and temperatures to meet your individual schedule needs The Quick Program Groups can be used to set the main portio...

Страница 10: ...sday Wednesday Thursday Friday Saturday Sunday Whole Week 4 Once you have finished your Quick Program Group or Individual Day selection Press the or button to change the time to the desired hour in one hour increments press the PROG button The minute portion of the setpoint time will begin flashing 5 Press the or button to change the time to the desired minute in 10 minute increments press the PRO...

Страница 11: ...the setpoint times and temperatures for the MORN DAY EVE and NIGHT setpoints for the Weekend group in the HEAT mode 9 Place the system switch in the COOL mode of operation The display will show COOL Follow steps 2 through 8 to program the setpoint times and temperatures for the Weekday and Weekend groups in the COOL mode 3 Press the or button to change the time to the desired hour in 1 hour increm...

Страница 12: ...button again as desired to adjust the set temperature 2 The display will return to normal operating mode after 15 seconds or you can press RETURN button 3 The program indicator MORN DAY EVE OR NIGHT will be flashing in the display indicating that a Temporary Program Override is in effect The Temporary Program Override will reset when the next setpoint time occurs or after 4 hours whichever comes f...

Страница 13: ...h once per second and then appear continuously in the display The keypad is now locked To unlock the keypad press and hold the and buttons together at the same time for 1 second The LOCK segment will disappear and the keypad will become unlocked 6 7 ADDITIONAL OPERATION FEATURES 6 cont Filter Check Monitor The Filter Check Monitor displays a reminder for required filter replacement or cleaning by ...

Страница 14: ...ill mechanically turn off if the room temperature raises higher than 99 F 37 C There is also a software feature that will automatically turn off the thermostat in HEAT mode if the temperature raises higher than 93 F 34 C WARNING Read BEFORE proceeding If the heating system is shut off by the High Temperature Safety Switch press the RESET button using a paper clip or a small pencil tip This will re...

Страница 15: ...tment 3 Install two new AA alkaline batteries into battery compartment Make sure to match the positive ends of the batteries with the positive terminals located in the battery compartment 4 Close battery compartment and verify that the low battery indicator does not appear in the display The Reset feature allows the user to completely reset the thermostat to register new manual switch settings 1 T...

Страница 16: ...rogram has been temporarily overridden and program indicator is flashing in the display Wait until next setpoint and the temporary override will expire or change setpoint temperature to desired comfort level Thermostat program is in Extended Hold Vacation Mode and HOLD and TEMP is showing in display Press HOLD button to release permanent hold and return the thermostat to normal program operation T...

Страница 17: ... and Setting Your Energy Saving Program sections of this manual If AC Power is present call a professional service technician to verify thermostat and system performance This is above the normal thermostat temperature setting range of 45 to 90 F 7 to 32 C HI is shown in the thermostat display where the room temperature is normally displayed The temperature sensed by the thermostat is higher than t...

Страница 18: ...The temperature sensed by the thermostat is lower than the 40 F 5 C lower limit of the thermostats display range The display will return to normal after the sensed temperature rises within the 40 to 99 F 5 to 37 C display range If the temperature in the controlled space seems to be normal wait for the thermostat to acclimate to the correct room temperature If the room seems to be colder than usual...

Страница 19: ... Note Eliminate connection to Y2 for units with single stage cooling R Y1 Y2 W2 G O B C W1 1st Stage Compressor Contact 2nd Stage Compressor Contactor Auxiliary Heat Relay stage 2 1st Stage Heat Relay Fan Relay Transformer Common required 24 VAC Neutral Hot 120 VAC ...

Страница 20: ...ovided it is returned postage prepaid to our warranty facility in a padded carton within the warranty period with proof of the original date of purchase and a brief description of the malfunction This limited warranty does not include the cost of removal or reinstallation WARRANTY YEAR LIMITED This warranty gives you specific legal rights and you may also have other rights that vary from state to ...

Отзывы: