USER MANUAL

Compatible with low voltage multi-stage 

heat / cool systems with up to two stages of 

heating and two stages of cooling.

 

READ ALL INSTRUCTIONS BEFORE PROCEEDING

© 2005 Braeburn Systems LLC • Patents Pending • All Rights Reserved.      Pub. No. 3100-100-006

WARNING!

Important Safety Information

•  Always turn off power to the air conditioning or heating system prior to  

  installing, removing, cleaning or servicing thermostat.

•  Read manual thoroughly prior to installing, programming or operating thermostat.

•  This thermostat is designed for use with a 24 Volt-AC low voltage multi-stage 

  heat / cool system.

•  Do not use this thermostat on systems with voltages higher than 30 Volt-AC.

•  This thermostat requires 24 Volt AC power for normal operation and control of  

  the heating or cooling system.

•  Wiring must conform to all building codes and ordinances as required by local  

  and national code authorities having jurisdiction. 

• Do not short (or jumper) across terminals on the gas valve or at the heating or  

  cooling system control board to test the thermostat installation. This could  

  damage the thermostat and void the warranty.

• Do not select COOL mode of operation if the outside temperature is below 50˚ F  

  (10˚ C). This could possibly damage the controlled cooling system and may  

  cause personal injury.

•  This thermostat should only be used as described in this manual. Any other use  

  is not recommended and will void the warranty. 

SPECIFICATIONS

1

•  Electrical Rating:  24 Volt AC (18-30 Volt AC)

       2 amp maximum load per terminal

       4 amp total maximum load (all terminals)

•  Control Range:  45˚ - 90˚ F (7˚ - 32˚ C)

•  Accuracy:   +/- 1˚ F (+/- .5˚ C)

•  AC Power:   18-30 Volt AC

•  Compatibility: Multi-stage heat / cool systems with up to two stages of heating    

  and two stages of cooling.

•  Terminations:  R, Y1, Y2, W1, W2, G, O, B, C

INSTALLATION

2

2.1

Replacing Existing Thermostat

1.

 Always turn off power to the air conditioning or heating system prior to removing  

  existing thermostat.

2.

 Remove the cover of your old thermostat and locate the wire terminals. Do not  

  remove wires from terminals yet.

3.

 Using small pieces of masking tape label wires prior to removal from terminals. Use  

  the chart below to determine the new terminal designations for your new thermostat.

4.

 After labeling and removing all wires from terminals, unscrew the existing thermostat  

  sub-base from wall. Make sure to secure wires to prevent them from slipping back  

  into the hole in the wall.

Old Terminal from 

New Terminal for

Existing Thermostat  New Thermostat  Terminal Description

R, V-VR or VR-R 

24 VAC

Y, Y1 or M 

Y1 

1st Stage Cooling

Y2 

Y2 

2nd Stage Cooling

W1 

W1 

1st Stage Heating

W2 or W-U 

W2 

2nd Stage Heating

G or F 

Fan Control

O or R 

Reversing Valve (Cooling)

Reversing Valve (Heating)

C, X or B 

Transformer Common

Premier Series

Non-Programmable

2 Heat / 2 Cool & Heat / Cool

Digital Thermostat

CONTENTS

SPECIFICATIONS
INSTALLATION
TESTING YOUR NEW THERMOSTAT
PROGRAMMING USER SETTINGS
ADDITIONAL OPERATION FEATURES
TROUBLESHOOTING
WIRING DIAGRAM

1

2

3
4
5
6
7

1

Содержание Premier 3100

Страница 1: ...ded and will void the warranty SPECIFICATIONS 1 Electrical Rating 24 Volt AC 18 30 Volt AC 2 amp maximum load per terminal 4 amp total maximum load all terminals Control Range 45 90 F 7 32 C Accuracy 1 F 5 C AC Power 18 30 Volt AC Compatibility Multi stage heat cool systems with up to two stages of heating and two stages of cooling Terminations R Y1 Y2 W1 W2 G O B C INSTALLATION 2 2 1 Replacing Ex...

Страница 2: ...The cooling system should stop within 90 seconds dependent on the setting of the Residual Cooling Fan Feature 7 Place the fan switch in the ON position The system blower should start 8 Place the fan switch in the AUTO position The system blower should stop Do not short or jumper across terminals on the gas valve or at the heating or cooling system control board to test the thermostat installation ...

Страница 3: ...ation 2 Press the or button to set the residual cooling fan delay to your desired setting of 0 disabled 30 60 or 90 seconds The default setting is 60 seconds During the COOL mode of normal operation the fan will stay on for 60 seconds after the cooling system has satisfied the setpoint temperature and has turned off the compressor This allows the system to provide higher efficiency during cooling ...

Страница 4: ...ill not start This indicates that the system is turned off at the thermostat Move the system selector switch to the HEAT or COOL position After the compressor short cycle protection 5 minute period expires the system should start within several seconds Thermostat turns heating or cooling system on too often or not often enough Increase or decrease first stage temperature differential setting as ap...

Страница 5: ...ere the room temperature is normally displayed The temperature sensed by the thermostat is higher than the 90 F 32 C upper limit of the thermostats display range The display will return to normal after the sensed temperature lowers within the 45 to 90 F 7 to 32 C display range Turn on the cooling system or use other methods to lower the temperature accordingly This condition could occur from the s...

Страница 6: ... or replace at its option any Braeburn thermostat under warranty provided it is returned postage prepaid to our warranty facility in a padded carton within the warranty period with proof of the original date of purchase and a brief description of the malfunction This limited warranty does not include the cost of removal or re installation This warranty gives you specific legal rights and you may a...

Отзывы: