background image

6

7

SYMPTOM

POTENTIAL SOLUTION

Thermostat turns 
heating or cooling 
system on too often or 
not often enough.

Increase or decrease temperature differential setting as 
appropriate to provide the desired performance level. See 

Setting Temperature Differential,

 section 4 of this manual.

SYMPTOM

POTENTIAL SOLUTION

Thermostat does not 
turn on heating or 
cooling system.

Check to see if 

OFF

 is shown in display. This indicates that the 

system is turned off at the thermostat. Move the system 
selector switch to the 

ON

 position. 

Compressor protection features may be in effect due to 
compressor short cycle conditions. See

 Compressor Protection 

Feature

 section for full explanation of this feature.

Heating or cooling system may be malfunctioning. Call a 
professional service technician immediately to verify system 
operation.

Low battery indicator is 
shown in thermostat 
display.

Replace batteries immediately to maintain proper system 
operation. See 

Battery Replacement, 

section 7 of this manual.

Thermostat will not 
allow me to program 
a setpoint temperature 
higher than 90˚ F (32˚ C).

This is above the normal thermostat temperature setting range 
of 45˚ to 90˚ F (7˚ to 32˚ C).

Thermostat will not 
allow me to program 
a setpoint temperature 
lower than 45˚ F (7˚ C).

This is below the normal thermostat temperature setting range 
of 45˚ to 90˚ F (7˚ to 32˚ C). 

Fan continues to run all 
the time whether the 
system is on or off.

Check that the fan control switch is in the 

AUTO

 position. This 

will allow the fan to run only when the heating or cooling 
system is turned on and running.

Check thermostat wiring to make sure that the fan control 
wiring is connected to the correct terminals on the wiring 
terminal block. See 

Installation 

and

 Wiring Diagrams sections

 

of this manual.

The room is too warm 
or too cold.

See 

Review Set Temperature, 

section 5 of this manual to verify 

the current setpoint and make any modifications that are 
necessary. 

HI

 is shown in the 

thermostat display 
where the room 
temperature is 
normally displayed.

The temperature sensed by the thermostat is higher than the 
90˚ F (32˚ C) upper limit of the thermostats display range. The 
display will return to normal after the sensed temperature 
lowers within the 45˚ to 90˚ F (7˚ to 32˚ C) display range.

This condition could occur from the system being turned off 
during an exceptionally warm period or upon installation when 
the thermostat has been stored for a long period of time in a 
warm vehicle or location prior to being installed. The 
thermostat is equipped with a mechanical high temperature 
safety switch that will turn off the thermostat should the 
temperature exceed 99˚ F (37˚ C).

LO

 is shown in the 

thermostat display 
where the room 
temperature is 
normally displayed.

The temperature sensed by the thermostat is lower than the 45˚ 

F (7˚ C) lower limit of the thermostats display range. The display 

will return to normal after the sensed temperature rises within 

the 45˚ to 90˚ F (7˚ to 32˚ C) display range. If the temperature in 

the controlled space seems to be normal, wait for the 

thermostat to acclimate to the correct room temperature.
This condition could occur from the system being turned off 

during a cold weather period or upon installation when the 

thermostat has been stored for a long period of time in a cold 

vehicle or location prior to being installed. The thermostat 

should be allowed to warm up prior to installation to allow 

proper heating control once installed.

Troubleshooting

8

Troubleshooting

8

cont.

OFF

 is shown in 

thermostat display 
and heating or cooling 
system will not start.

This indicates that the system is turned off at the thermostat. 
Move the system selector switch to the 

ON 

position.

It is possible that the batteries are drained and not providing 
power for the thermostat to control the system. Replace 
batteries immediately to maintain proper system operation. 
See 

Low Battery Detection, 

section 6 of this manual.  If you 

replace the batteries and the display does not appear, call a 
professional service technician to verify thermostat and 
system performance.

Thermostat display 
is blank.

Содержание Builder 1005

Страница 1: ...ubleshooting Wiring Diagrams 1 2 3 4 5 6 7 8 9 MODEL Before Installing Programming or Operating PLEASE READ ALL INSTRUCTIONS 1005 WARNING Important Safety Information Always turn off power to the air conditioning or heating system prior to installing removing cleaning or servicing thermostat Read this manual thoroughly prior to installing programming or operating this thermostat This thermostat is...

Страница 2: ...et the thermostat to register your thermostat switch configurations prior to programming any user settings Gently press the RESET button on the front of the thermostat using a paperclip or a small pencil tip Function Status After Reset Operation Mode Normal Operating Mode Room Temperature 70 F 21 0 C to be renewed within 5 seconds Setpoint Temperature According to system switch 62 F 17 0 C for Hea...

Страница 3: ...ease the button and press the or button again as desired to adjust the set temperature 2 The display will return to normal operating mode after 5 seconds 3 The SET indicator will turn off in the display indicating that the current temperature shown in the display is the room temperature Temperature Adjustment 5 Additional Operation Features 6 5 Battery Replacement 7 1 Open front cover and locate t...

Страница 4: ...the thermostat display where the room temperature is normally displayed The temperature sensed by the thermostat is higher than the 90 F 32 C upper limit of the thermostats display range The display will return to normal after the sensed temperature lowers within the 45 to 90 F 7 to 32 C display range This condition could occur from the system being turned off during an exceptionally warm period o...

Страница 5: ... from accident alteration neglect misuse improper installation or any other failure to follow Braeburn installation and operating instructions Braeburn Systems LLC agrees to repair or replace at its option any Braeburn thermostat under warranty provided it is returned postage prepaid to our warranty facility in a padded carton within the warranty period with proof of the original date of purchase ...

Отзывы: