Installer Guide

Non-Programmable Thermostats

1

 

Specifications      

Installation and Wiring      

Quick Reference

 

Installer Settings      

System Testing

• Possible electric shock or damage to equipment can occur.

• Disconnect power before beginning installation.

Caution

This thermostat requires 24 Volt AC Power or 2 properly installed “AA” Alkaline 

batteries for proper operation. When connecting 24 Volt AC Power the batteries may 

be installed as a backup.

For use only as described in this manual. Any other use will void warranty.

3020

 

Single Stage Heat / Cool Conventional 

 

or Heat Pump

3220

 

Up to 3 Heat / 2 Cool Heat Pump

 

Up to 2 Heat / 2 Cool Conventional

Warning

For installation by experienced service technicians only.

®

  

 

 

This thermostat is compatible with:

   

•  Single stage heat / cool conventional and heat pump systems

   

•  Conventional systems up to 2 stages of heating and 2 stages of cooling (3220 only)

   

•  Heat pump systems up to 3 stages of heating and 2 stages of cooling (3220 only)

   

•  250 – 750 millivolt heating only systems

   

•  2 or 3 wire hydronic zone systems

  

Electrical and control specifications:

   

•  Electrical Rating:  24 Volt AC

   

•  1 amp maximum load per terminal

   

•  AC Power:  18 – 30 Volts AC

   

•  DC Power:  3.0 Volt DC (2 “AA” Alkaline Batteries Included)

   

•  Control Range:  45° – 90° F (7° – 32° C)

   

•  Temperature Accuracy:  +/- 1° F (+/- .5° C)

   

•  Outdoor Temperature Display Range:  -40° - 120° F (-40° - 49° C)

   Terminations

   

•  3020:  G, Rc, Rh, W1, O/B/V3, Y1, C, S1, S2

   

•  3220:  G, Rc, Rh, W1/E/W3, W2, O/B/V3, Y1, Y2, C, L, S1, S2

1

Specifications

3020W-100-01

Model number is located on back of thermostat.

P

REMIER

S

ERIES

Содержание 3020

Страница 1: ...g For installation by experienced service technicians only This thermostat is compatible with Single stage heat cool conventional and heat pump systems Conventional systems up to 2 stages of heating and 2 stages of cooling 3220 only Heat pump systems up to 3 stages of heating and 2 stages of cooling 3220 only 250 750 millivolt heating only systems 2 or 3 wire hydronic zone systems Electrical and c...

Страница 2: ...t 24 Volt AC Cooling Transformer Dual Transformer Systems Only Rh Input Power Connection 24 Volt AC Heating Transformer or Millivolt Power Source G Output Fan Control W1 Output Conventional Heat Relay O B V3 Output O Cool Active Reversing Valve B Heat Active Reversing Valve V3 Zone Valve Power Close Y1 Output Compressor Relay C Input 24 Volt AC Transformer Common S1 S2 Connect Your Wires 3 Input O...

Страница 3: ...former 4 Connect Y2 only if a second cooling compressor is being used Provide disconnect and overload protection as required 2 HEAT 2 COOL Single or Dual transformer Set System Type to 22CONV Rh 24 Volt AC Power heating transformer note 2 Rc 24 Volt AC Power cooling transformer note 2 W1 Heat Relay Stage 1 W2 Heat Relay Stage 2 Y1 Compressor Relay Stage 1 Y2 Compressor Relay Stage 2 note 4 G Fan R...

Страница 4: ...r Wire O B Changeover Valve note 2 Y1 Compressor 1 Relay 1st stage heating cooling Y2 Compressor 2 Relay 2nd stage heating cooling G Fan Relay C 24 Volt AC Transformer Common note 1 L Optional System Fault Monitor note 4 NOTES Heat Pump Systems 1 Optional 24 Volt AC common connection 2 O cool active or B heat active is selected in the Installer Settings menu 3 Install a field supplied jumper betwe...

Страница 5: ...t for 1st stage Electric heating 8 Emergency Heat HE EMER HE EMER Select for Electric Emergency Heat Fan Control note 3 HG EMER Select for Gas Emergency Heat 9 Reversing Valve REVO REVO Select for cool active Reversing Valve O terminal O B Terminal note 4 REVB Select for heat active Reversing Valve B terminal 10 Fossil Fuel AE AUX AE AUX Select for Electric Auxiliary heat with compressor Backup He...

Страница 6: ...de air temperature is less than the selected setting of 15 F to 50 F 9 C to 10 C 19 Auxiliary Heat Balance Point notes 3 9 Locks out the use of the auxiliary heat stage when the outside air temperature exceeds the selected setting of 70 F to 40 F 21 C to 4 C NOTE This balance point overrides the fossil fuel compressor lockout in option 10 If this option is set to gas and the outdoor temperature is...

Страница 7: ... system and may cause personal injury This thermostat includes an automatic compressor protection feature to avoid potential damage to the compressor from short cycling When testing the system make sure to take this delay into account NOTE The compressor delay can be bypassed by pressing the reset button on the front of the thermostat All user settings will be returned to factory default however a...

Отзывы: