5
Bradley Corporation • 215-1372 Rev. F; EN 03-045
Terreon® Tri-Fount™ Wall-Hung Washfountain with Battery-Operated Infrared Control
Installation Instructions
MF2939/BIR
9-17-2003
Installation Instructions continued . . .
Step 2: Install Vernatherm™ valve
1. Connect the braided hoses and
pipe cross to the Vernatherm™
valve (see Figure 2).
2. Install the two pipe clamps on
the Vernatherm™ assembly
(Figure 2).
3. Install the Vernatherm
assembly by placing the two
pipe clamps on the mounting
studs in the middle of the
pedestal frame (Figure 2).
4. Install the two 1/4-20 nuts and
washers supplied to secure the
pipe clamps to the mounting
studs.
5. Connect the rough-in supply
piping after you have read the
following:
• The stop/check valve must be
used in order to provide proper cross flow checking. No other stops are required. These stops
MUST be fully opened for proper operation of the metering valves.
• The thermostatic mixing valve requires at least 115° F water from the hot water side for proper
operation. As with all lavatories, there will be a delay in obtaining warm water. If the hot water
is too far away from the washfountain, a circulating pump may be required.
FOR SINGLE TEMPERED SUPPLY (OPTIONAL):
Connect the 90° elbow to the 1/2" tempered
supply line as shown in Figure 2a.
Figure 2
Filter Washer
Vernatherm™
Assembly
1/2"
Elbow
Pipe
Clamp
Mounting
Stud
Nut and
Washer
Braided Hoses
Pipe
Cross
Stop/Check
Figure 2a
90° Elbow
To Supply Line
Braided Hoses
From Valve Box
Check/Stop
Cross
Optional Single Tempered Supply