Installation 

P.O. Box 309

Menomonee Falls, WI 53052 USA

800 BRADLEY (800 272 3539)

+1 262 251 6000

bradleycorp.com

TDWL22

Terreon

®

 Deep Well Lavatory

Table of Contents

Supplies Required  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Components   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
Dimensions   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4
Rough-In   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5
Bowl Mounting with In-Wall Carrier  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6-7
Bowl Mounting with Backplate Weldment  .  .  .  .  .  .  .  .  .  .  .  . 8
Drain Assembly  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 9
Cleaning and Maintenance   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 10

TDWL22 shown with optional S53-325 faucet .

WARNING

Make sure that all water supply lines have been flushed and then completely turned off before beginning 
installation. Debris in supply lines can cause valves to malfunction.

Turn OFF electrical power to the electrical outlets, then unplug all electrical units prior to installation. 
Electrical power MUST remain off until installation is complete.

Hardware supplied by installer must be appropriate for wall construction. Wall anchors used must have a 

minimum pull-out rating of 1,000 lbs.

IMPORTANT

Read this entire installation manual to ensure proper installation. When finished with the installation, file this 

manual with the owner or maintenance department.

Separate parts from packaging and make sure all parts are accounted for before discarding any packaging 

material. If any parts are missing, do not begin installation until you obtain the missing parts.

Product warranties may be found under "Products" on our website at www.bradleycorp.com.

215-1734 Rev. D; ECN 15-10-002
© 2017 Bradley
Page 1 of 9 

2/20/2017

Содержание Terreon TDWL22

Страница 1: ...electrical outlets then unplug all electrical units prior to installation Electrical power MUST remain off until installation is complete Hardware supplied by installer must be appropriate for wall c...

Страница 2: ...ber Standard PVC P Trap 269 1697 Optional Chrome Plated Brass P trap S29 094 Strainer Assembly 269 1597 Surface Mounted Bracket S45 1976 Locking Device qty 2 Leveling Screw qty 4 Prepack 269 1712 incl...

Страница 3: ...allation TDWL22 Bradley 215 1734 Rev D ECN 15 10 002 2 20 2017 3 TDWL22 Dimensions Top View 22 559mm 20 508mm Side View 24 610mm 22 559mm 12 305mm Front View 16 3 4 429mm 13 5 8 346mm 10 254mm 3 3 4 9...

Страница 4: ...ap with AC adaptor 46 1168mm 34 864mm 27 699mm 23 584mm 8 203mm 1 24mm 2 64mm 2 64mm 5 140mm 5 140mm C L 21 546mm 18 470mm Hot Supply Zone Nominal Copper Tubing Stub out 2 from Wall Cold or Tempered S...

Страница 5: ...2 Places 17 1 4 219mm Before beginning bowl mounting install an in wall carrier supplied by installer to the wall following the manufacturer s instructions ex Josam 17100 202 or equivalent For standa...

Страница 6: ...each in wall carrier arm C Adjust the two leveling screws from beneath the bowl on each in wall carrier arm to level the bowl if necessary Refer to the in wall carrier instructions for additional moun...

Страница 7: ...3 8 unscrewed B 1 4 3 8 Leveling Screw Leveling Screw Bracket Arm Locking Device Arm Pocket C L Bowl Mounting with Backplate Weldment 2b A Slide the bracket arms into the collars on the backplate weld...

Страница 8: ...TDWL22 Installation 8 2 20 2017 Bradley 215 1734 Rev D ECN 15 10 002 Rubber Washer Fiber Washer Tailpiece P trap Strainer Drain Assembly 3...

Страница 9: ...ng Daily or as often as needed use a solution of warm water and soap detergent or ammonia Apply the cleaning solution per the manufacturer s instructions and always use a soft cloth or sponge to avoid...

Отзывы: