Installation
To attach Plastic Dust Cover to existing unit:
NOTE: For clarity, only the bowl, handle and ball valve from the existing eyewash unit are shown in
the illustration. Refer to the installation manual provided with the eyewash unit (if available) for
eyewash assembly information.
NOTE: Main water supply to the unit should be turned off before beginning installation.
1. Detach the flag handle from the
ball valve.
2. Turn the eyewash assembly
approximately 360° to loosen the
assembly from the bowl and allow
the bowl to move freely.
3. Position the dust cover assembly
on top of the eyewash bowl.
4. Using the holes in the dust cover
bracket as a template, drill two
1/4" holes in the eyewash bowl.
5. Attach the dust cover to the bowl
with the 1/4" screws and secure
the cover with the 1/4" acorn nuts
(hardware provided by Bradley).
6. If necessary, rotate the eyewash
bowl so that the dust cover’s
hinge bracket is positioned at the
rear of the unit.
7. Retighten the eyewash assembly
to the bowl by rotating it
approximately 360°.
8. Install the stop bracket on the ball
valve.
NOTE: Bracket tabs must face ball
valve and be oriented 180° from the
stops on the flag handle.
9. Attach the dust cover linkage to
the handle stem and reattach the
flag handle.
10. Turn on the water supply and
check for leaks and adequate
water flow.
S45-1964
Dust Cover Retrofit Kit
P.O. Box 309, Menomonee Falls, WI 53052-0309
Phone: 1-800-BRADLEY Fax: (262) 251-5817
http:\\www.bradleycorp.com
215-1435 Rev. D; EN 07-520
© 2007 Bradley Corporation
Page 1 of 3
8/27/07
EYEWASH
DUST COVER
(154-140)
LINK
ASSEMBLY
(S70-170)
FLAG
HANDLE
BALL
VALVE
SCREW (160-444)
HEX NUT (161-062)
UTILITY HINGE
(220-128)
BRACKET
(140-910)
SCREW (160-310)
JAM NUT (161-060)
HEX NUT (161-078)
1/4-20 ACORN
NUT (161-052)
1/4-20 SCREW
(160-389)
STOP BRACKET
(140-695)