Servicing of Lights
S19-324D2 LED Arrays (Type 4X)
A
De-power the control box by
observing standard lock-out tag-out
practices .
B
To disconnect the wire leads of the
light requiring the bulb to be replaced,
use a small blade screwdriver to
depress the orange terminal release
tab adjacent to the wire's location .
With the tab fully depressed, the
wire can be easily removed from the
terminal location .
C
Remove the nut on the stem of
the light which attaches it to the
enclosure . Remove the entire light .
D
Remove the gasket (if present) to
expose the four screws which retain
the dome .
E
Remove the screws, take off the
dome and the LED array is now
visible . Press and turn the LED array
to remove . Replace as needed with
the same size LED array and color .
F
Reverse the disassemble process to
reinstall the light . Inspect all gaskets
and seals to ensure the integrity of
the unit .
G
Check that the signaling station is
functioning properly once the power
is restored by activating the fixture
attached to the signaling station .