11

Installation 

S19-323, S19-324

Bradley • 

215-1846 Rev. G: ECO 20-05-028 

6/11/2020

S19-323 Service Parts and Components

2

3

1

4

5

82

80

81

83

36

84

Item Part No.  Qty.

Description

1

S90-566

1

Sub Assy, Signaling Station

2

257-006

1

Signal Light, Amber - Flashing

3

268-002

1

Buzzer, 24VDC-Tone 1

4

269-2454

1

Cord Grip, 3/4"-4x-200

5

269-524

1

Cond Cable, 6'

36

269-2460

1

Plug, 3/4" Conduit, NEMA 4X

60

140-1156

1

Bracket, Alarm Box GA

61

S90-634

1

General Area Hardware Kit

Item Part No.  Qty.

Description

80

269-1421

1

Flowswitch, 1-1/4" T-DPDT

80

269-1522

1

Flowswitch, 1/2" - T-DPDT

81

269-1902

1

Junction Box, Conduit Outlet

82

269-1903

1

Cover

83

269-514

1

Cable Receptacle

84

269-518

1

Reducing Bushing

Items #60 and #61 are not shown and shipped 
loose.

Part No.  Qty.

Description

160-467

4

Screw, 1/4-20x3/4 PN 300 SS

142-002AV

4

Washer, .265x.500x.0.63 Flat 304SS

161-060

4

Nut, 1/4-20 SS Nylon Insert

269-594

2

U-Bolt, SS

161-065

4

Nut, 3/8-16 Hex 18-8SS

161-171

2

3/4 NPSM Conduit Locknut

S90-634 General Area Hardware Kit (Item 61)

Содержание NEMA 3R

Страница 1: ...MA 3R S19 324 NEMA 4X Emergency Signaling System Table of Contents Pre Installation Information 2 3 Components 4 5 Install Flow Switch and Mount Assembly 6 Connect Signaling Assembly to Flow Switch 7...

Страница 2: ...e beginning installation and after installation is complete Test the unit for leaks and adequate water flow Main water supply should be ON at all times unless system is being serviced Provisions shall...

Страница 3: ...res require a minimum of 30 PSI 0 21MPa flowing pressure Weekly activation must be conducted on all plumbed emergency equipment to ensure a suitable flushing fluid supply is present and any sediment b...

Страница 4: ...1mm NPT Hub Plugged Brass Sensor Body Brass Adapter and Tee NEMA 3R Junction Box and Cover Electrical Quick Disconnect Male 3 76mm 4 11 16 119mm Red Blue Black Remote Sensing 12 3 8 315mm System is pr...

Страница 5: ...0 9 16 269mm Beacon Light Type 4X Shown Optional NPT Hub Plugged Brass Sensor Body Brass Adapter and Tee NEMA 4X Junction Box and Cover Electrical Quick Disconnect Male 3 5 16 84mm Red Blue Black Remo...

Страница 6: ...nections C Choose a location for mounting the alarm For best visibility the signaling system should be mounted at least 7 above ground level The signaling system may be mounted directly to the drench...

Страница 7: ...termine mounting location of selector switch and size flexible cable length accordingly Hook up the wires from the provided flexible cable to control board see wiring diagram while the cover is off At...

Страница 8: ...low will automatically reset the silence feature The alarm signaling system is designed to work properly even if both the eyewash and drench shower are used simultaneously The alarm will continue to o...

Страница 9: ...ensure the integrity of the unit G Check that the signaling station is functioning properly once the power is restored by activating the fixture attached to the signaling station S19 323 Signal Light...

Страница 10: ...Component failure Check light connections and filament in the light Area light does not operate No power to the signal station Check that the circuit breaker or fuse is supplying power to the signal...

Страница 11: ...ket Alarm Box GA 61 S90 634 1 General Area Hardware Kit Item Part No Qty Description 80 269 1421 1 Flowswitch 1 1 4 T DPDT 80 269 1522 1 Flowswitch 1 2 T DPDT 81 269 1902 1 Junction Box Conduit Outlet...

Страница 12: ...32 269 1316 1 Conduit Nipple 3 4 x 6 33 169 1145 1 Elbow Pulling Conduit Item Part No Qty Description 34 269 2156 1 Close Nipple 3 4 Conduit 36 269 2460 Plug 3 4 Conduit NEMA 41 229 010 1 Selector Sw...

Отзывы: