Installation
LD-5010
Bradley
• 215-1869 Rev. B; ECN 17-11-004B
8/24/2017
11
Structural Rough-Ins
(mm)
CODE
DESCRIPTION
QTY.
A
3/8" wall anchors with a minimum pull-out force of 1,000 lbs. per local codes
2 per bracket
C
Install wall anchor with a minimum pull-out force of 100 lbs. per local codes at locations shown
4
S
#10 Wall Anchors for Soap Control Box Bracket
4
S1
#10 Wall Anchors for Soap Tank Bracket (100 lb pull out force)
4
13-1/4" min
(337)
13-1/4" min
(337)
9"
(229)
33-1/2"
(851)
Deck Height
21-3/4"
(552)
15-5/8"
(396)
3/4"
(19)
15-9/16"
(394)
10-3/8"
(264)
3-1/4"
(83)
5-1/2"
(140)
13"
(330)
10-3/8"
(264)
5"
(127)
3-1/2"
(89)
A
A
S
S
C
C
S1
S1
A
A
C
C
CL
Typical OmniDeck rough-
ins for single WB-TR1 bowl
are shown. Other multiple-
bowl rough-ins are similar.
Finished Floor
RIM HEIGHT
VERTICAL HEIGHT ADJUSTMENTS
FIXTURE STYLE
34"
No Adjustment
Standard Height, ADA, TAS
31
Subtract 3"
Juvenile, ADA and TAS
33-1/16"
Subtract 15/16"
OBC
34-1/16"
Add 1/16"
BCBC and QBC
33-7/8"
Subtract 1/8"
CSA