SS-3N/BIR3/STD, SS-3N/BIR3/WH
Installation
10
9/7/2018
Bradley
• 215-1496 Rev. J; ECN 17-08-026
H
C
This valve is NOT factory preset. Upon installation, the temperature of this
valve must be checked and adjusted to ensure delivery of a safe water
temperature. Water in excess of 110°F (43°C) may cause scalding.
7
Adjust the Temperature
A
Loosen the cap screw about ¼"
(4–6 turns) and lift up the cover
(do not remove).
B
Using the cover, turn the
cartridge gently until desired
water temperature is reached. Do
not turn past stops as this may
damage the unit. Push the cover
down and tighten the screw.
C
Reinstall the valve bracket. Turn on the water supply to the Express and check for
leaks. Push the operating buttons of each station until all the air is purged from
the lines and water is flowing smoothly. Reinstall the access panel.