background image

Installation 

P.O. Box 309

Menomonee Falls, WI 53052 USA

800 BRADLEY (800 272 3539)

+1 262 251 6000

bradleycorp.com

215-1807 Rev. F: ECN 19-08-037F

© 2020 Bradley

Page 1 of 40 

3/2/2020

ELX-2

Express

®

 Lavatory System – ELX-Series

Système lave-mains Express

®

 – Série ELX

Sistema de lavabo Express

®

 – Serie ELX

WARNING

Turn OFF electrical power to the electrical outlets, then unplug all electrical units prior to installation. 

Electrical power MUST remain off until installation is complete. 
Installer’s hardware must be appropriate for wall construction. Wall anchors must have a minimum pull-out 

rating of 1,000 lb.

NOTICE

Make sure that all water supply lines have been flushed and then completely turned off before beginning 

installation. Debris in supply lines can cause valves to malfunction.

IMPORTANT

Read this entire installation manual to ensure proper installation. When finished with the installation, file 

this manual with the owner or maintenance department. Compliance and conformity to local codes and 

ordinances is the responsibility of the installer. Product warranties may be found under “Products” on our 

website at bradleycorp.com.
Separate parts from packaging and make sure all parts are accounted for before discarding any packaging 

material. If any parts are missing, do not begin installation until you obtain the missing parts. 
For standard height mounting, do not exceed the recommended 33.5" distance from the fixture rim to the 

finished floor.

Содержание Express ELX Series

Страница 1: ...l water supply lines have been flushed and then completely turned off before beginning installation Debris in supply lines can cause valves to malfunction IMPORTANT Read this entire installation manua...

Страница 2: ...ns 17 18 Raccordements 19 22 Montage du support 23 Assemblage du bouchon de trop plein 24 Assemblage de l coulement 24 Fixation de la vasque 25 Tamis et siphon en P 25 Fair couler l eau pour r gler la...

Страница 3: ...iner Standoff Hex SS 6 32 x 1 Screw 6 32 x 1 1 4 Pan Included in Prepack S45 2778 TMV Valve NPTM Outlet S45 2701 Hose Prepack S45 2730 TMV Supply Connections Plastic Hose Hose Prepack S45 2731 Tempere...

Страница 4: ...mum pull out rating of 1 000 lb 4 fasteners and wall anchors minimum pull out rating of 100 lb hot cold or tempered stub out s 1 NPT drain stub out s OPTIONAL 2 110V GFCI protected electrical outlets...

Страница 5: ...ture Style Notes 33 No Adjustment Standard ADA TAS At least one basin must meet dimensional requirements and have proper reach knee and toe clearance 30 Subtract 3 Juvenile ADA TAS At least one basin...

Страница 6: ...building codes 2 31 793 11 295 3 84 Areas highlighted in gray require sufficient backing compliant with local building codes C L 19 502 B B 12 311 12 311 C C 19 502 24 610 Finished Floor 24 610 26 673...

Страница 7: ...51 16 420 16 420 5 141 24 616 20 525 Rim Height Approx Soap Battery Box Location 14 373 Finished Floor A F F F F A G G E E H C CODE DESCRIPTION QTY A 1 NPT Drain Stub out 2 from wall individual waste...

Страница 8: ...0 5 141 30 770 24 616 20 525 Approx Soap Battery Box Location Rim Height Approx Soap Battery Box Location 14 373 Finished Floor A F F F F A G G G G E E H C CODE DESCRIPTION QTY A 1 NPT Drain Stub out...

Страница 9: ...ng 15 397 4 121 5 142 3 79 3 89 4 114 17 435 27 707 33 851 5 141 24 616 22 570 20 525 Rim Height 14 373 Finished Floor F F F F E E H B C CODE DESCRIPTION QTY B 1 NPT Drain Stub out 2 from wall combine...

Страница 10: ...xample anchor locations shown A Locating Notch Using the location notches on the wall bracket draw a vertical line down at least 12 B Measure down 10 from the bottom of the wall bracket and draw a hor...

Страница 11: ...225 For ease of drain installation lay the bowl on its back 3 Drain Assembly Thread screw into drain adapter until it becomes fully engaged A Thread the standoff onto the now fully engaged screw B O R...

Страница 12: ...ff on the drain adapter A Position bowl above wall bracket Press firmly on the back of the bowl to seat the bowl flange into the wall bracket lip Ensure bowl is level A Secure the bowl to the wall anc...

Страница 13: ...ws and finishing washers provided starting with the left or right side first A Adjust Temperature with Water Running H C A Loosen Cap Screw about 1 4 4 6 turns and lift up cover do not remove B Using...

Страница 14: ...el Material Description Stainless steel is extremely durable and maintenance is simple and inexpensive Proper care particularly under corrosive conditions is essential Always start with the simplest s...

Страница 15: ...ce de d bris dans les conduites peut causer un mauvais fonctionnement des vannes IMPORTANT Veiller lire ce manuel en entier pour assurer une installation correcte Lorsque l installation est termin e r...

Страница 16: ...inox 6 32 x 1 Vis cylindrique bomb e n 6 32 x 1 1 4 Inclus dans la trousse S45 2778 Vanne TMV Sortie 1 2 NPTM S45 2701 Trousse tuyaux S45 2730 Tuyau en plastique Trousse tuyaux S45 2731 Raccordements...

Страница 17: ...000 lb Quatre 4 chevilles d ancrage et vis de 1 4 r sistance nominale l arrachement d au moins 0 44 kN 100 lb Tubulure s 1 2 chaud froid ou temp r Tubulure s d coulement 1 1 2 NPT EN OPTION Deux 2 pri...

Страница 18: ...andard TAS At least one basin must meet dimensional requirements and have proper reach knee and toe clearance 775mm 30 1 2 Retrancher 76mm 3 ADA enfants TAS At least one basin must meet dimensional re...

Страница 19: ...essitent un renfort suffisant conforme au code du b timent en vigueur Hauteur du rebord Ajustements de la hauteur Type d appareil 851mm 33 1 2 Pas d ajustement Standard ADA TAS 775mm 30 1 2 Retrancher...

Страница 20: ...Arriv es d eau chaude froide de nominal comp dia ext tubulure 51mm 2 du mur 1 E Prise lectrique 110 V disjoncteur protection DDFT GFI pour robinets et distributeurs de savon lectriques uniquement 2 F...

Страница 21: ...ide de nominal comp dia ext tubulure 51mm 2 du mur 1 E Prise lectrique 110 V disjoncteur protection DDFT GFI pour robinets et distributeurs de savon lectriques uniquement 2 F 10 Anchors for Faucet Con...

Страница 22: ...our une hauteur standard ADA et TAS CODE DESCRIPTION QT B coulement 1 NPT tubulure 51mm 2 du mur option raccordements d vacuation combin s tuyaux couper sur place 1 H C Arriv es d eau chaude froide de...

Страница 23: ...tre d exemple A Encoche de positionnement En partant des encoches de positionnement du support mural tracer une ligne verticale vers le bas de 12 305mm au moins B Mesurer 10 267mm vers le bas partir d...

Страница 24: ...stallation de l coulement poser la vasque sur le dos 3 Assemblage de l coulement Engager la vis fond dans l adaptateur d coulement A Visser l entretoise sur la vis pr sent compl tement engag e B Joint...

Страница 25: ...a vasque au dessus du support mural Appuyer fermement sur l arri re de la vasque pour l engager compl tement dans le support mural V rifier que la vasque est de niveau A Fixer la vasque sur les chevil...

Страница 26: ...fournies en commen ant du c t gauche ou du c t droit A Faire couler l eau pour r gler la temp rature H C A Desserrer la vis t te de 1 4 6mm environ 4 6 tours et soulever le capuchon ne pas l enlever B...

Страница 27: ...retien de l acier inoxydable Description du mat riau L acier inoxydable est extr mement durable et son entretien est simple et peu co teux Il est essentiel de l entretenir correctement en particulier...

Страница 28: ...Los desechos acumulados en las tuber as de suministro pueden provocar defectos en el funcionamiento de las v lvulas IMPORTANTE Lea en su totalidad este manual de instalaci n para garantizar una instal...

Страница 29: ...o inoxidable n 6 32 x 1 Tornillo n 6 32 x 1 1 4 de cabeza troncoc nica Se incluyen en el conjunto preempaquetado S45 2778 V lvula TMV salida de 1 2 NPTM S45 2701 Conjunto preempaquetado de manguera S4...

Страница 30: ...de pared clasificaci n de extracci n m nima de 0 44 kN 100 libras Salientes de agua caliente y fr a o temperada de 1 2 Salientes para drenaje de 1 1 2 NPT OPCIONAL 2 tomacorrientes el ctricos protegi...

Страница 31: ...t ndar y TAS At least one basin must meet dimensional requirements and have proper reach knee and toe clearance 775mm 30 1 2 Reste 76mm 3 ADA para menores y TAS At least one basin must meet dimensiona...

Страница 32: ...te suficiente para cumplir con los c digos locales de construcci n Altura del borde Ajustes de altura vertical Estilo del accesorio 851mm 33 1 2 Sin ajuste Est ndar ADA y TAS 775mm 30 1 2 Reste 76mm 3...

Страница 33: ...iduales 2 H y C Suministros de agua fr a y caliente de nominal di m ext comp de salen 51mm 2 de la pared 1 E Tomacorriente protegido por interruptor GFI de 110 V solo llave y jab n CA 2 F 10 Anchors f...

Страница 34: ...os de agua fr a y caliente de nominal di m ext comp de salen 51mm 2 de la pared 1 E Tomacorriente protegido por interruptor GFI de 110 V solo llave y jab n CA 2 F 10 Anchors for Faucet Control Box Ins...

Страница 35: ...os brazos de los desechos combinados se cortar n en el campo 1 H y C Suministros de agua fr a y caliente de nominal di m ext comp de salen 51mm 2 de la pared 1 E Tomacorriente protegido por interrupto...

Страница 36: ...las ubicaciones de los anclajes A Ranura de referencia Con las ranuras de referencia del soporte de pared dibuje una l nea vertical de al menos 12 305mm B Mida 10 267mm desde la parte inferior del so...

Страница 37: ...e coloque la palangana sobre su respaldo 3 Conjunto de desag e Enrosque el tornillo en el adaptador de desag e hasta que encaje completamente A Enrosque el separador en el tornillo ahora completamente...

Страница 38: ...rte de pared Presione firmemente la parte posterior de la palangana para asentar su brida en el borde del soporte de pared Aseg rese de que la palangana est nivelada A Fije la palangana a los anclajes...

Страница 39: ...comience con el lado izquierdo o el lado derecho A Ajuste la temperatura con el agua corriendo H C A Suelte el tornillo de cabeza unos 1 4 6mm 4 a 6 giros y levante la cubierta sin quitarla B Utiliza...

Страница 40: ...antenimiento para el acero inoxidable Descripci n del material El acero inoxidable es extremadamente duradero y su mantenimiento es simple y econ mico Sin embargo un cuidado adecuado en especial bajo...

Отзывы: