background image

Installation

S53-325

7

Bradley Corporation • 215-1641Rev. C; EN 09-02-0005

11/17/09

Batteries not inserted correctly 

Remove cover from battery box and check that the batteries have been inserted to the 
correct orientation and are making connection to the contacts. Refer to the battery icons 
located on the base of the battery box tray.

Improper or poor connection 
to power supply

Check that the connection from the battery box is fully inserted into the female connector 
on the valve control box and assure the connector round thumbnut is fully fastened. 

Faucet not working 

(No flashing red indicator 
located inside clear cover 
of valve control box)

Low batteries

If red indicator is flashing 5 times every 4 seconds, replace with new Alkaline batteries.

Water source valves turned off

Open water source valves and check that there is water flow. 

Sensor shorted to ground or 
unit unable to calibrate

If red indicator is flashing once or multiple times every 4 seconds, there is a problem with 
the installation and the sensor is shorted. To verify the control box is working correctly, 
carefully disconnect the black sensor wire from the connection washer. With the wire 
disconnected, touch the connector at the end of the black wire with your fingers. The 
sensor should activate and water should come on. Let go of the connector and the water 
should shut off. If the unit works as described above and it malfunctions when you 
reconnect the black sensor wire to the spout assembly, then there is an error in the spout 
and cover plate installation. If the faucet does not activate as described when touching the 
sensor connector, then you have a grounding issue or there is a broken sensor wire (see 
troubleshooting below).  

Improper ground connection

There is improper earth grounding if the faucet activates when you touch any of the steel 
braided supply hoses, the brass fitting on the valve box, or the mixing valve. Verify that the 
ground clamp has been installed and recheck the connections. Verify the clamp is tightly 
fastened directly to the copper pipe for a proper ground connection. Reset the unit 
following procedure below*.

Broken or corrupt sensor wire 
or defective valve box 
electronics.

If the connector has broken off of the black sensor wire or the valve box appears to be 
defective please contact Bradley Technical Service. Do not attempt to repair the valve box 
or sensor wire.

Faucet not working and 
no water flows when 
activated

(Red indicator is flashing)

Problem

Cause

Solution

Troubleshooting Guide

Poor sensor washer and wire 
connection

Verify the brass nuts that fasten the connection washer are fully tightened. Reconnect the 
sensor wire to the washer. Press reset button on valve control box after making any 
adjustments

Insufficient ground connection

Verify that the earth ground clamp has been installed and recheck the connections. Verify 
the clamp is tightly fastened directly to the copper pipe for a robust ground connection. 
Reset the unit following procedure below*.

Intermittent cycling and/or 
water runs on after 
activation

Isolation parts are not installed 
or not installed correctly.

If the faucet activates when you touch the sink, the unit installation is improper. Check that 
isolation components are used and installed correctly. Verify the sink ground connection is 
in place and installed properly.

Intermittent cycling and 
/or faucet actuation is 
overly sensitive 

Drain grounding not 
connected or assembled.

Check that the drain ground is assembled to the threaded portion of the metal drain ring 
(not on the pipe) and is connected to the tab on the valve control box. Press reset button 
on valve control box after making any adjustments. 

Water stays on or runs on 
after you pull your hand 
away

There is sensor short to ground 
or unit is not calibrating.

Water stays on

Debris or particulate matter is 
trapped in valve

Turn off water source valves. Remove aerator from end of the spout and examine for dirt 
and particulates. Inspect and clean input dirt filter. Reinsert filter and turn water source 
back on. Actuate faucet several times without the aerator installed to flush any debris from 
the valve mechanism until dripping has ceased. Reinstall aerator.

Water is dripping from 
spout when not actuated

Dial set to the "open" position 
or not turned to the full "auto" 
position

Turn the knob on the side of the valve control box fully to the "auto" position (until it hits 
the stop) and actuate the faucet by placing your hand near the spout. Water should stop 
running and unit will return to the normal idle operation mode once you remove your hand 
from the spout.

Dial not turned to the full 
"auto" position

Turn the knob on the side of the valve control box fully to the "auto" position (until it hits 
the stop) and actuate the faucet several times by placing your hand near the spout. Water 
should stop running or dripping and unit will return to the normal idle operation mode once 
you remove your hand from the spout.

 Reset the unit following procedure below*. If water continues to run, there is an error in the 
installation and grounding scheme (see above).

* How to Reset the Unit: 

Disconnect power source for 10 seconds. The valve will close and the water will stop running. After 10 seconds, reconnect power 

supply. Let unit recalibrate for another 20 seconds and verify faucet activation.

REF

751

135

Содержание Aerada 1200 Series

Страница 1: ...ith manufacturer s recommendations The supply piping to these devices must be securely anchored to the building structure to prevent unnecessary movement of the installed device when operated by the user Use extreme caution when installing the device to prevent damage to the exposed significant surface Separate parts from packaging and make sure all parts are accounted for before discarding any pa...

Страница 2: ...ENSOR WASHER Optional AC Adapters in lieu of Battery Box SINGLE UNIT ADAPTER 153 443 6 UNIT ADAPTER BOX 153 444 WIRE ASSEMBLY FOR 6 UNIT ADAPTER BOX 269 1841 ORDER ONE PER FAUCET 3 ref 5 ref 269 1889 GROUNDING KIT Aerator Kit 269 1957 includes Aerator 1 5 GPM Aerator Key Spout Kit 269 1954 includes Items marked with 2 M4 x 12mm screws Valve Control Module Kit 153 447 includes Control Module Ground...

Страница 3: ... PLATE STUDS AND SECURE TRIM PLATE TO SINK USING METAL WASHERS AND HEX NUTS Optional Trim Plate Removal Red Plastic Screw Spacers Gasket and Faucet Spacers Trim Plate Long Trim Plate Screws A Remove and discard Long Trim Plate Screws and white plastic screw spacers B After removing Trim Plate re attach gaskets and faucet spacer using shorter M4 x 12MM screws supplied Do not re install screw spacer...

Страница 4: ...ODULE TO FAUCET SHANK 2 Attach Activation Hardware to Faucet Shank 3 in 1 Washer BRASS MOUNTING NUT SENSOR WIRE CONNECTION WASHER BRASS MOUNTING NUT A ATTACH GROUNDING HARDWARE TO SHANK IN THE ORDER SHOWN B ATTACH ACTIVATION HARDWARE TO SHANK IN THE ORDER SHOWN S53 325 Installation Tab on 3 in 1 Washer must be positioned 180 degrees opposite tab on Sensor Connection Washer ...

Страница 5: ...s using Trim Plate refer to Step C SINK GROUNDING TAB WASHER U TAB CONNECTION RING TERMINAL SIDE SINK GROUND WIRE A CONNECT SINK DRAIN GROUND WIRE TO SINK GROUNDING TAB WASHER C PLACE RING TERMINAL SIDE ON ONE OF THE THREADED STUDS AND FASTEN WITH LOCK WASHER AND NUT B CONNECT THIS END OF SINK GROUND WIRE TO ONE TAB ON U TAB CONNECTION D ATTACH DRAIN WIRE CLAMP TO SINK DRAIN Connect Sensor Wire BL...

Страница 6: ...ING 2 PHILLIPS SCREWS C CONNECT BATTERY BOX CONNECTOR OR AC POWER CONNECTOR TO VALVE CONTROL MODULE POWER CONNECTION B SECURE BATTERY COMPARTMENT TO WALL USING WALL ANCHORS OR DOUBLE SIDED TAPE INSERT 4 D CELL ALKALINE BATTERIES AND REPLACE COVER 7 6 Install Earth Ground Assembly A CONNECT EARTH GROUNDING CLAMP TO COLD WATER SUPPLY BETWEEN SHUT OFF VALVE AND WALL PLATE B CONNECT EARTH GROUNDING CO...

Страница 7: ...he brass nuts that fasten the connection washer are fully tightened Reconnect the sensor wire to the washer Press reset button on valve control box after making any adjustments Insufficient ground connection Verify that the earth ground clamp has been installed and recheck the connections Verify the clamp is tightly fastened directly to the copper pipe for a robust ground connection Reset the unit...

Отзывы: