EcoPower

®

 Hybrid Ventilator 

Installation Manual 

 

 

 

 

 

 

 

 

 

 

 

PRINT IN COLOUR 

Содержание EcoPower 400

Страница 1: ...EcoPower Hybrid Ventilator Installation Manual PRINT IN COLOUR...

Страница 2: ...ED TO INSTALL THIS PRODUCT IF THE ABOVE REQUIREMENTS ARE UNABLE TO BE MET 2 PACKING LIST Check Before Commencing Included Parts Additional Materials Required Not Supplied a FASTENERS Quantity and Type...

Страница 3: ...packaging using a crane or similar equipment to roof mounting location prior to handling the product Caution The ventilator top surface dome can be easily scratched or deformed when placed upside down...

Страница 4: ...ov au heights d This product must be installed by a qualified installer and all electrical wiring must be undertaken by a qualified electrician e This hybrid ventilator uses 220V 240V AC power for the...

Страница 5: ...ventilator demand The make up air location should be positioned at optimum height to provide efficient sweeping of the area The illustrations below provide a number of generic ventilator and make up a...

Страница 6: ...mers between the purlin on the either side of the opening Do not cover the openings EP900 If the purlin spacing is larger than 1000mm trimmers are required Install the trimmers between the purlin on t...

Страница 7: ...ch is level horizontal it is recommended that an electronic or spirit level is used to ensure that the top edge of the throat is horizontal in all directions Secure the Varipitch angle With the varipi...

Страница 8: ...a natural gutter to release any trapped condensation g Secure Varipitch to Flashing Secure the varipitch to the flashing using the recommended number of screws shown in the table below DO NOT seal thi...

Страница 9: ...r of fasteners shown in the table below i Sealing is crucial for this product to ensure no leaking occur during its lifespan Ensure the following areas are sealed Go to Section 6 for Additional Requir...

Страница 10: ...nd less than 2 pans width cut a square hole for 2 pans Note EP400 EP600 If purlin spacing larger than 600mm trimmers may be required Install the trimmers between the purlin on the either side of the o...

Страница 11: ...the hole in the back flashing tray Secure the ventilator s flashing to the back flashing tray using the recommended number of fasteners shown in the table below Note Always provide 1 dry pan on each...

Страница 12: ...the Varipitch When a Varipitch throat is being used place the Varipitch on the flashing and rotate the top and bottom halves until the top of the Varipitch is level horizontal it is recommended that a...

Страница 13: ...a natural gutter to release any trapped condensation j Secure Varipitch to Flashing Secure the varipitch to the flashing using the recommended number of screws shown in the table below DO NOT seal th...

Страница 14: ...this product to ensure no leaking occur during its lifespan Ensure the following areas are sealed Go to Section 6 for Additional Requirements for Cyclonic Wind Regions Model Fasteners to secure Turbin...

Страница 15: ...esignated replace guidance in Section 6 7 with specific information in this Section Fastener Selection a Fix Flashing to roof with 14G Class 3 or 4 Tek screws Locate 4 close to Varipitch and 26 around...

Страница 16: ...Straps to the inside top edge of the Varipitch down to the underside of a roof purlin as shown above e Fix both cyclone fixing straps to the inside of the varipitch with at least 4 x 6 4 AS rivets Two...

Страница 17: ...17 Cyclone Strap Assembly Cross Section View 1 Cyclone Strap 4 x 6 4 AS Rivets Purlin 2 x M8 Nuts M8 x 25 Hex Head Screw...

Страница 18: ...18 Cyclone Strap Assembly Cross Section View 2 Cyclone Strap Varipitch Ventilator Throat...

Страница 19: ...all are in situ and well sealed Flashing Connections check joints that are meant to be sealed remain sealed and that those that are meant to be unsealed are clear of obstruction Sparkguard if provide...

Страница 20: ...y protection While it is recommended that silicon be applied over roofing screws it is more reliable to use high quality blind rivets or roofing screws with integrated washers 7 Failure to Use Ventila...

Страница 21: ...ensation Ventilators with dampers which are unable to allow the warm humid air escape through the ventilator may be at risk of condensation This is due to the un insulated damper becoming the interfac...

Страница 22: ...oduced in any form without prior written consent of CSR Bradford Recommendations and advice regarding the use of the products described in this brochure are to be taken as a guide only and are given w...