Bradford White TTW RG1PV55H6N-475 Скачать руководство пользователя страница 1

238-51010-00D  REV 3/17 

POWER VENT GAS WATER HEATER 

 
A Spanish language version of these instructions is available by contacting the 
company listed on the rating plate. 
La version espanola de estas instrucciones se puede obtener al escribirle a la 
fabrica cuyo nombre aparece en la placa de especificaciones. 
 

 

   WHAT TO DO IF YOU SMELL GAS 

 

Do not try to light any appliance. 

 

Do not touch any electrical switch; do not use any 
phone in your building. 

 

Immediately call your gas supplier from a  neighbor’s 
phone. Follow the gas supplier's instructions. 

 

If you cannot reach your gas supplier, call the fire 

 

department. 

Installation and service must be performed by a qualified 
installer, service agency or the gas supplier. 

 

For your family’s comfort, safety and convenience we  
recommend this water heater be installed and serviced by a 
plumbing professional.

 

INSTALLATION AND OPERATION 

INSTRUCTION MANUAL

 

FOR YOUR SAFETY 

 

   Do not store or use gasoline or other flammable, 

combustible, or corrosive vapors and liquids in the 
vicinity of this or any other appliance. 

WARNING:

 If the information in these instructions is not 

followed exactly, a fire or explosion may result causing 
property damage, personal injury, or death. 

Содержание TTW RG1PV55H6N-475

Страница 1: ...one Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas...

Страница 2: ...e installation of this water heater We require that you carefully read this manual as well as the enclosed warranty and refer to it when questions arise If you have any specific questions concerning y...

Страница 3: ...g 19 Combustion Air Supply 21 Water Connections 23 Gas Connections 26 Electrical Connections 27 Wiring Diagram 28 GENERAL OPERATION 29 Lighting and Shutdown Instructions 30 Thermostat Adjustment 31 Bu...

Страница 4: ...h an installation may create a hazardous condition and will nullify the warranty Do not use this appliance if any external part to the tank has been submerged in water You should contact a qualified s...

Страница 5: ...46 cm above the floor and must be located or protected to avoid physical damage For other installations refer to local codes In the absence of local codes the water heater must be installed in complia...

Страница 6: ...th little or no odor to reveal their presence NOTE DAMAGE TO THE WATER HEATER CAUSED BY EXPOSURE TO CORROSIVE VAPORS IS NOT COVERED BY THE WARRANTY DO NOT OPERATE THE WATER HEATER IF EXPOSURE HAS OR W...

Страница 7: ...to an adequate drain The piping must be at least 3 4 inch 1 9 cm in diameter and pitched for proper drainage It is recommended that a minimum clearance of 4 inches 10 2 cm be provided on the side of t...

Страница 8: ...appliance by at least 3 inches 7 6 cm in any direction or if the appliance is to be installed in an alcove or closet the entire floor must be covered by the panel The minimum clearances to combustibl...

Страница 9: ...y other appliance 12 inches 30 cm 4 feet 1 2m below or to side of opening 12 inches 30 cm above opening K Clearance to a mechanical air supply inlet 6 feet 1 83 m 3 feet 91 cm above if within 10 feet...

Страница 10: ...F WATER HEATER and CLEARANCES and with National Fuel Gas Code and local codes WARNING Risk of carbon monoxide poisoning or fire due to joint separation or pipe breakage This water heater must be prope...

Страница 11: ...rs and cements All approved primers and cements are to be used within their marked time limitations Approved Venting Materials For installations in the US only PVC DWV ASTM D 2665 PVC Sch 40 80 120 AS...

Страница 12: ...ater is a power vented appliance and is designed to vent its products of combustion through 3 inch 7 6 cm or 4 inch 10 2 cm diameter vent pipe to the outdoors This water heater may be either vented ho...

Страница 13: ...ER VENT PIPE Terminating of 90 Elbows excl vent term Maximum straight Length ft m Min straight Length ft m 55 and 75 gal Through the Wall 1 175 53 3 10 3 1 Through the Wall 2 170 51 8 10 3 1 Through t...

Страница 14: ...connections must be leak checked with a soap and water solution upon initial start up of the water heater Any leaks must be repaired before continuing operation of the water heater CONNECTION TO A 3 7...

Страница 15: ...cement to secure the 90 vent terminal provided with the water heater to the vent connector The distance between the edge of the 90 vent terminal and the exterior wall see Figure 3 must be 1 in 2 5 cm...

Страница 16: ...l codes and or The National Fuel Gas Code ANSI Z223 1 Latest Edition or CGA CAN B149 Installation Code latest edition Figure 4 NOTE For installations requiring both horizontal and vertical runs the fo...

Страница 17: ...all at a height greater than or equal to 12 inches 30 5 cm above the ground or anticipated snow level the installation must be modified as shown below see Figure 5 Refer to Table 3 for maximum venting...

Страница 18: ...TIONS Terminating Reduce 4 inch to 3 inch Reduce 10 1 cm to 7 6 cm of Elbows excl vent term Max straight Length ft m Min straight Length ft m 55 and 75 gal 2 90 Elbows with 1 90 Elbow 1 160 48 8 10 3...

Страница 19: ...applicator tools to ensure proper preparation and joining of pipe and fittings a Cutting Tools i A square cut must be achieved with a miter box saw or pipe cutter to ensure a proper mating with the f...

Страница 20: ...at around the end of the pipe 4 Joining a Joints should be made immediately after cement is applied b After fully inserting pipe into fitting socket hold joint together for about 15 to 20 seconds c Re...

Страница 21: ...e hazardous to life Such a condition often will result in a yellow luminous burner flame causing carbon build up or sooting of the combustion chamber burners and flue tubes with possible damage to the...

Страница 22: ...ectly or by ducts with the outdoors or spaces crawl or attic that freely communicate with the outdoors 1 When directly communicating with the outdoors each opening must have a minimum free area of 1 i...

Страница 23: ...It is imperative that heat is not applied to the nipples containing a plastic liner If this water heater is installed in a closed water supply system such as one having a back flow preventer in the co...

Страница 24: ...sure relief valve into the opening provided and marked for this purpose on the water heater Note Some models may already be equipped or supplied with a combination temperature and pressure relief valv...

Страница 25: ...s 130 F 54 C About 30 seconds 135 F 57 C About 10 seconds 140 F 60 C Less than 5 seconds 145 F 63 C Less than 3 seconds 150 F 66 C About 1 seconds 155 F 68 C About 1 second WARNING Hydrogen gas can be...

Страница 26: ...hreaded joints of the gas piping must be resistant to the action of liquefied petroleum gases propane gas DO NOT apply pipe dope to the gas valve inlet and make certain that no pipe dope has become lo...

Страница 27: ...ater and use the flexible cord provided Do not plug the line cord into a receptacle that can have its power supply interrupted by a switch that is used to turn on and off lights If wiring in conduit i...

Страница 28: ...28 Wiring Diagram Figure 6...

Страница 29: ...ter heater 3 Close the cold water supply shut off valve 4 Open the drain valve on the water heater by turning the stem counter clockwise The drain valve has threads on the end that will allow the conn...

Страница 30: ...30 Lighting and shutdown instructions...

Страница 31: ...point Dark Battleship Grey faceplate is approximately 180 F maximum set point DANGER Hotter water increases the risk of scald injury Scalding may occur within 5 seconds at a temperature setting of 14...

Страница 32: ...n adjustable air shutter See Figure 8 At periodic intervals a visual check of the main burner and pilot flames should be made to determine if they are burning properly The main burner flame should lig...

Страница 33: ...burner flames to determine that they are burning properly See Burner Flame Check If sooting or other burner anomalies are evident shut down the water heater by turning off the gas per the instructions...

Страница 34: ...ontact the water supplier or local plumbing inspector on how to correct this situation Do not plug the combination temperature and pressure relief valve outlet 9 A combination sacrificial anode rod ho...

Страница 35: ...7 621 238 7 634 976 7 650 859 7 665 210 7 665 211 7 699 026 7 866 168 7 900 589 7 971 560 7 992 526 8 082 888 8 146 772 Other U S and Foreign patent applications pending Current Canadian Patents 2 092...

Страница 36: ...mperature switch not working open position 1 Vent blockage or improper vent configuration 2 Pressure switch tubing kinked or blocked 3 Blower not spinning up to speed 4 Vent temperature too high 5 Fau...

Страница 37: ...rify control is not wet or physically damaged 2 Reset control on off switch 3 Replace electronic module if 8 3 error persists Eight flashes four flashes three second pause Gas valve fault detected 1 V...

Страница 38: ...Left 2 Pressure Switch not shown 12 Inner Door Right 3 Blower temp switch not shown 13 Screw Inner Door 4 Flue Baffle or Flue Core 14 Outer Door 5 Flue Baffle Reducer 15 Screw Outer Door 6 Anode Nippl...

Страница 39: ...sed for boiler treatment must not be introduced into potable water used for space heating 3 This water heater must not be connected to an existing heating system or component s previously used with a...

Страница 40: ...40 NOTES...

Отзывы: