“THERMOSTATIC”

MODELS COVERED:

EFT-5500-4-S-10         240V
EFT-6500-4-S-10         240V
EFT-7500-4-S-10         240V 
EFT-9500-4-S-10         240V
EFT-8300-2-S-10         208V
EFT-6000-5-S-10         277V
EFT-8000-5-S-10         277V
EFT-9000-5-S-10         277V
EFT-10000-5-S-10       277V

ELECTRIC INSTANTANEOUS WATER 

HEATER

INSTALLATION GUIDE AND OWNERS MANUAL

READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING TO INSTALL OR OPERATE 
THIS WATER HEATING UNIT.  IF YOU DO NOT FOLLOW THE SAFETY RULES, THE 
UNIT WILL NOT OPERATE PROPERLY AND COULD CAUSE DEATH, SERIOUS 
BODILY INJURY AND OR PROPERTY DAMAGE.

READ ALSO THE ENCLOSED WARRANTY CARD.  WARRANTY OF THIS WATER 
HEATING UNIT WILL DEPEND ON PROPER INSTALLATION AND OPERATION.  THE 
WARRANTY SHALL BE VOID IF THE DESIGN HAS BEEN ALTERED IN ANY WAY 
WHATSOEVER.  THE MANUFACTURER OF THIS UNIT WILL NOT BE LIABLE FOR 
ANY DAMAGES BECAUSE OF FAILURE TO COMPLY WITH THE INSTALLATION AND 
OPERATING OUTLINED ON THE FOLLOWING PAGES. 

THE INSTALLATION MUST CONFIRM WITH THE INSTRUCTIONS IN THIS MANUAL; 
ELECTRIC COMPANY RULES; AND LOCAL CODES, OR IN THE ABSENCE OF LOCAL 
CODES, WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE.  A 
COPY OF THE NATIONAL ELECTRICAL CODE IS AVAILABLE FROM 
UNDERWRITERS LABORATORIES, 333 PFINGSTEN ROAD, NORTHBROOK, IL, 
60062

.

IF ASSISTANCE IS REQUIRED OR ANY QUESTIONS ARISE RELATING TO THE 
INSTALLATION OR THE PERFORMANCE OF THIS UNIT,  CONTACT TECHNICAL 
SERVICE DEPARTMENT TOLL FREE AT 1-800-334-3393.         

HAVE THE INFORMATION LISTED BELOW BEFORE CALLING:

MODEL NO.

SERIAL NO.

INSTALL DATE

.

Содержание Kwickshot EFT-5500-4-S-10

Страница 1: ...AND OPERATION THE WARRANTY SHALL BE VOID IF THE DESIGN HAS BEEN ALTERED IN ANY WAY WHATSOEVER THE MANUFACTURER OF THIS UNIT WILL NOT BE LIABLE FOR ANY DAMAGES BECAUSE OF FAILURE TO COMPLY WITH THE IN...

Страница 2: ...use as possible For example directly beneath a sink is ideal Do not install the unit above a faucet as a siphoning effect will drain the unit causing heating element burn out 2 This unit must only be...

Страница 3: ...full flow ball valve type in both the inlet and outlet lines This allows the unit to be isolated for maintenance figure 2 4 When all plumbing is complete inspect the system for water leaks at all the...

Страница 4: ...t 1 Wire entry into the unit should be made through the lower right hand corner of the backplate via one of the knockout holes provided 2 The mains wires should be connected to the slots in the termin...

Страница 5: ...MENT SCREW HOT WATER OUTLET PRE HEATED COLD WATER INLET MINIMUM SETTING MAXIMUM SETTING THE TEMPERATURE CONTROLLING POTENTIOMETER IS A PRECISION COMPONENT ADJUST GENTLY AND DO NOT TURN BEYOND THE MIN...

Страница 6: ...ght to begin pulsing Repeat until the indicator light is pulsing regularly This indicates that the temperature has stabilized at the set temperature Check that the water temperature is sufficient for...

Страница 7: ...HMS 7 8 OHMS 10 11 OHMS IF RESISTENCE OF THE ELEMENT IS MUCH GREATER THAN THESE READINGS CALL TECHNICAL SUPPORT NO HEAT OR LOW TEMERATURE INDICATOR LIGHT ON A WATER FLOW TOO HIGH REDUCE WATER FLOW BY...