background image

 

BR3010 

LED 10W CCT All in One Floodlight  

BR3020 

LED 20W CCT All in One Floodlight  

BR3030 

LED 30W CCT All in One Floodlight  

 

BR3050 

LED 50W CCT All in One Floodlight  

 

BR3001 

Plug in PIR  

 
 

CCT All in One Floodlight  

Features 

Dimensions  

 

Colour temperature selectable 

 3000K/4000K/5000K 

 

Plug and play IP65 PIR connection 

 PIR sold separately  

 

Integrated IP65 connector to terminate the cable directly into  

 

Toughened glass diffuser and aluminium housing  

 

Ideal and energy efficient LED technology replacement for 
traditional flood lights  
 

 

 

Width (W) 

Depth (D) 

Height (H) 

10W 

109mm 

60mm 

156.5mm 

20W 

126mm 

60mm 

166mm 

30W 

164mm 

60mm 

197mm 

50W 

189mm 

60mm 

217mm 

 

Safety Instructions 

1.

 

These instructions should be read carefully and retained after installation for future reference and maintenance. 

2.

 

Ensure that the mains power is switched off before carrying out installation or maintenance.  

3.

 

Check that the total load on the circuit including this luminaire does not exceed the rating of the circuit cable, fuse or circuit breaker 

4.

 

It is recommended that luminaires are installed and fitted by a qualified electrician ensuring the installation complies with the current 
edition of IET wiring regulations - BS 7671. This luminaire is electrical class 1 construction and must be earthed. 

5.

 

Ensure all electrical connections are secure and that there are no loose strands. 

Environmental Instructions  

This product may contain substances that can be hazardous to the environment if not disposed of properly. Electrical and electronic 
equipment should never be disposed of with general household waste but must be separated for its correct treatment and recovery. 
Where possible recycle your packaging. 

Installation Instructions 

 Standard Flood Light  

 

SUGGESTED METHOD OF INSTALLATION 
Read instructions and check you have all the tools and accessories 
to complete the installation safely and in compliance with current 
electrical standards.  

1.

 

Switch off the electricity at the fuse box by removing the  
relevant fuse or switching off the circuit breaker before 
proceeding with the installation.  

2.

 

On rear of the flood light, unscrew the connector cover to 
reveal the wiring terminals. Terminate one end of a 3-core 
cable into the connector terminals, ensuring the correct 
polarity is observed and the unit is earthed. Replace the 
connector cover back in place to sure the cable is secure, 
and the IP rating of the connector is maintained.   

3.

 

Use the mounting bracket as a template to mark hole 
centres. Drill the fixing holes and fit suitable wall plugs. 
Secure the metal bracket in place with screws.  

4.

 

Using a suitable hex key, loosen the bracket bolts on side 
of the floodlight to adjust the floodlight to desired angle 

5.

 

Terminate the mains supply cable into the terminals in the 
suitable junction box.  The live conductor should be in-line 
with the circuit breaker and any isolation switches 
 

Standard Wiring 
- Brown to live 
- Blue to neutral 
- Green / Yellow to earth 

 

6.

 

Use the CCT changing rocker switch to select the desired 
colour temperature. Switch on the power supply and 
check the operation.

 

 

 

Отзывы: