background image

 

Page 11 

6.2. Dip switch positions 

 

In addition to running the necessary wires for the desired mode, positioning the three dip switches located on the 
lock printed circuit board determines the operation. These are accessed by removing the cover.  

MARKINGS S1, S2 AND M ARE FOUND ON THE PRINTED CIRCUIT BOARD.

 

 

Switches S1 

and

 S2

 are used to set the timed re-lock. If an unlock signal is given to the lock but the door is not 

opened the YD25K can automatically lock itself again after a selected time. This ensures that a door cannot be left 
unsecured  if it  has  been  unlocked  but  not  opened.  The  timer  is factory  set  to  9  seconds  but  0,  3,  and  6  second 
options are offered and selected by positioning the dip switches accordingly. 

Switch M

 is used to select fail safe or fail secure mode. 

This is factory set as ordered and should not need to 

be moved.

 

 

TIMED RELOCK

 

0 second 

 

3 second 

 

6 second 

 

9 seconds - default

 

SWITCH POSITIONS

 

S1 On & S2 On

 

S1 Off & S2 On

 

S1 On & S2 Off

 

S1 Off & S2 Off

 

 

MODE

 

Fail Safe

 

Fail Secure

 

3 WIRE MODE

 

M Off

 

M On

 

2 WIRE MODE

 

N/A

 

M On

 

 

7. OPERATION 

 

7.1. Three wire mode (Recommended) 

 
In  either  fail  safe  or  fail  secure  configuration,  maintained  connection  of  ‘1’  to  ‘2’  will  keep  the  YD25K  unlocked 
regardless of the door position.  The following scenarios assume that the control signal is open at the start of the 
operation sequence as a maintained connection will cause the lock to stay unlocked indefinitely. 
 

7.1.1. Fail safe operation  

 

Assume the door is closed and locked. M

omentarily connecting ‘1’ and ‘2’ unlocks the door for a period of 9 seconds. 

After the 9 seconds has elapsed if the door has not been opened the YD25K automatically locks again. If the door 
has opened within the 9 second window (which is the case in normal operation) the timed re-lock is overridden and 
automatic relocking occurs as soon as the door is closed. On closing, full power is applied to the YD25K 9 times in 
15  seconds  before  the  current  is  reduced  and  the  lock  goes  into  a  holding mode to minimize  heating  and  power 
consumption. The YD25K will remain unlocked as long as the door is open. 
 

7.1.2. Fail secure operation 

 
Assume the door is closed and locked. M

omentarily connecting ‘1’ and ‘2’ unlocks the door and over a 9 second 

period full power is applied to the lock 5 times. If the door remains closed, after 9 seconds has elapsed the YD25K 
automatically locks again. If the door has opened within the 9 second window (which is the case in normal operation) 
the YD25K will remain unlocked and in a holding mode until the door is closed again and automatic re-locking occurs.  
 

7.2. Two wire mode 

 

In installations where running three wires to the lock is not possible or desired the YD25K can operate effectively on 
two wires. Although the functions are reduced, as seen in the table below, controlling the lock this way still offers a 
high security locking solution. 
 

FEATURES 

Multiple re-lock 

(fail safe) 

Multiple unlock 

(fail secure) 

Auto re-lock 

Anti-Tamper 

Adjustable timed 

re-lock 

3 WIRE MODE 

Yes 9x 

Yes 5x 

Yes 

Yes 

Yes 

2 WIRE MODE 

Yes 5x 

Yes 5x 

N/A 

Yes 

No 

 

Содержание YD25K

Страница 1: ...INSTALLATION AND OPERATING INSTRUCTIONS Solenoid Dropbolt YD25K...

Страница 2: ...oduct is carrying the CE Mark in accordance with the related European Directives Responsible for CE Marking is BQT Solutions SEA Pte Limited 41B Neil Road 03 01 Singapore 088824 The complete EU Declar...

Страница 3: ...INSTALLATION ASSESSMENT 5 4 1 MECHANICAL 5 4 2 ELECTRICAL 6 5 INSTALLATION 6 5 1 MORTISE INSTALLATION 6 5 1 SURFACE INSTALLATION 8 6 WIRING 10 6 1 THREE WIRE CONNECTION 10 6 2 TWO WIRE CONNECTION FAI...

Страница 4: ...ng unlocking attempts Adjustable timed re lock Current reduction circuitry Door position and bolt position monitors High physical strength 10 000N 2 PRODUCT UNBOXED The YD25K is supplied with four 10G...

Страница 5: ...the YD25K will be mortised or surface mounted to the door door frame Mortise installation ensures a discrete solution as the lock and strike plate can be embedded into the door and frame however in s...

Страница 6: ...these connections to integrate into access control or alarm systems to provide full monitoring Finally the correct gauge of wire needs to be chosen as when connecting the power wires and to the lock v...

Страница 7: ...ebris and deep enough to allow the lock pin to fully extend when locked 5 1 2 Wiring the lock Wires are run out from the back of the mortise and following the connection guide on the locks cover conne...

Страница 8: ...e The housing has two holes that accept the stepped washers from the inside and once the housing is in place the screws can be tightened with a 2 Phillips head screwdriver through the outside holes On...

Страница 9: ...ousings are supplied with self adhesive tape With the backing removed the housing can be applied directly to the glass A flat stainless steel dress plate is fitted on the opposite of the glass to give...

Страница 10: ...ected to terminals 1 and 3 Wire links not supplied are connected from terminals 2 to 11 and 1 to 9 for fail safe Additionally manual override of the lock is achieved by utilising the key cylinder elec...

Страница 11: ...1 Fail safe operation Assume the door is closed and locked Momentarily connecting 1 and 2 unlocks the door for a period of 9 seconds After the 9 seconds has elapsed if the door has not been opened the...

Страница 12: ...A dry cloth can be used to polish the stainless steel face plate and strike plate as required This lock contains components that are subject to wear based on usage doorway operation and installation...