background image

Drilling template 

 

20mm (0.79”) diameter hole for wire entry 

 

2 x 4 mm (0.16”) diameter holes for mounting screws 

 

Inner reader dimension is 88mm x 88 mm (3.47" x 3.47") 

 

Assemble reader outer dimension is 90mm x 90mm (3.54” x 3.54”) 

 

Reader corner radius is 4mm (0.16”) 

 

 

 

 
 
 
Specifications 

Output protocols 

Wiegand 26-199bit, RS485 or custom configuration (Model 

dependent) 

 

BT815-WG/ 

MiP5/CSN5 

BT815-D/D2 

BT815 

BT815-BM 

Power requirement 

12V DC 

6-18V DC 

7-16V DC 

Current 

consumption 

103mA (Avg) 

145mA (Peak) 

157mA (Avg) 

174mA (Peak) 

38mA (Avg) 

80mA (Peak) 

45mA (Avg) 

135mA (Peak) 

Read range 

20-40mm (0.8”-1.6”) at 12V DC depends on the type of card 

used 

Operating 

temperature 

-25’C to +65’C (-13’F to 149’F) 

Relative humidity 

90% max, operating non-condensing 

Reader dimensions 

Standard: 90mm(L) x 90mm(W) x 27mm(D) (3.54”x3.54”x1.06”) 

Slim Line: 90mm(L) x 90mm(W) x 20mm(D) (3.54”x3.54”x0.79”) 

Status LED 

Green & Red 

Audible tone 

Internal and external buzzer control 

Colour finish 

Charcoal & Ivory 

IP rating 

IP65 

 

Information obtained in this document is subject to change without notice. 

 

For further technical information, visit our website at www.bqtsolutions.com or email 

[email protected]

 

Alternatively contact us at one of our global locations 

 

AUSTRALIA & PACIFIC 

BQT Solutions (Australia) Pty Limited 

Level 1, 82 Waterloo Road 

Macquarie Park, NSW 2113, Australia 

Phone: +61 (0)2 8817 2800 

Fax: +61 (0)2 8817 2811 

Email: [email protected] 

 

 

EUROPE AND MIDDLE EAST 

BQT Solutions (UK) Limited 

Regal House, 70 London Road 

Twickenham, TW1 3QS 

United Kingdom 

Phone: +44 (0)20 8622 4428 

Fax: +44 (0)20 8622 4401 

Email: [email protected] 

 

GREATER ASIA 

BQT Solutions Singapore Office 

Mediapolis 

71 Ayer Rajah Crescent #03-03 

Singapore 139951 

Phone: +65 6220 7970 

Fax: +65 6220 7656 

Email:  [email protected] 

 

 

 
 
 

 

 
 
 
 

Copyright © 2012 BQT Solutions Limited. BQT Solutions and the BQT solutions logo are registered trademarks of BQT Solutions (Australia) Pty Ltd. 

Wiring diagram 

 

Note: 

 

A shielded cable is recommended to be used. The shield is connected to controller 0V reference 

 

Maximum wiegand data cable length: 150 meters (500 feet)  

 

Buzzer and LED are activated when buzzer and LED line go below 2.5V. 

 

RS485 lines and Relay lines are only for optional use.  

 

Some models have additional wires/connectors which are not specified in the diagram above. These wires are for other 
requirements. DO NOT connect them unless specified from BQT Solutions or a BQT authorized distributor. Any damage 
caused by incorrect connection will void the warranty 

 

Terminate or insulate all un-used wires

 

 

Regulatory Information

 

C-Tick

: This device is C-Tick complied.  

CE

: The device has passed all relevant tests and obtained CE approval. 

FCC

: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) this device 

may not cause harmful interference and 2) this device must accept any interference received, including interference that 
may cause undesired operation of the device.  
Warning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 
15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential 
installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in 
accordance with the instructions, may cause harmful interference to radio communications. However, there is no 
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to 
radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try 
to correct the interference by one or more of the following measures: 
-Reorient or relocate the receiving antenna. 
-Increase the separation between the equipment and receiver. 
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 
-Consult the dealer or an experienced radio/TV technician for help. 
Any changes or modifications not expressively approved by BQT Solutions could void the user’s authority to operate this 
equipment.

 

 
 

 

                             

 

 
 

 
 

 

 
 
 

5

 