Страница 1: ...BAN 56 Z I 31030 CARBONERA TREVISO ITALIA TEL 39 0422 445363 FAX 39 0422 398646 EMAIL info bpstecnologie com PLEASE NOTE THE INSTRUCTIONS GIVEN HEREIN APPLY ONLY TO THE COUNTRY MARKED ON THE PLATE STUCK ON THE APPLIANCE ...

Страница 2: ... 145 84 55 TANGENTIAL FANS Number of revolutions 1 64 45 84 55 1 1 VOLTAGE RATING 220 240 V AC 50 60 Hz INSTALLED ELECTRIC POWER Watt 80 100 NOISE LEVEL AT 3 m IN STANDARD INSTALLATION dB a 36 38 WEIGHT Kg 19 26 COMBUSTION AIR REQUIRED VOLUME mc h 4 8 SMOKES MASS OUTPUT gr sec 1 46 2 92 FEEDING PRESSURE mbar COUNTRY CATEGORY G 20 G 25 G 30 G 31 ITALY II 2H3 20 30 37 FRANCE II 2Er3 20 25 28 37 BELG...

Страница 3: ...2 P R E S T I G E 2 G L O B A L V I E W Pict 1 ...

Страница 4: ...3 P R E S T I G E 4 G L O B A L V I E W Pict 2 ...

Страница 5: ... 300 mm Maximum 800 mm SUPPLIED PIPE L 500 mm OPTION PIPE L 800 mm L SIZE Minimum 50 mm Maximum 300 mm WALL INSTALLATION SMOKES EXHAUST AIR SUCTION DIRECT TO FROM OUTSIDE WALL INSTALLATION SMOKES EXHAUST COMBUSTION AIR SUCTION THROUGH THE OUTLET WINDOW Pict 3 ...

Страница 6: ...O WALLS Pict 4 The heaters of the PRESTIGE series are independent forced air convectors fitted with atmospheric burner and fan expressly designed for room heating These C 13 type appliances are sealed with respect to the room where they ve been installed in with concentric combustion air suction pipes and smokes exhaust pipes wall outlet Pict 3 4 They are PRESTIGE 2 and PRESTIGE 4 INSTRUCTIONS ...

Страница 7: ... different use is not allowed as it might be dangerous Always keep this handbook near convector In case convector was placed in houses where disabled people and or children live then place it safely away from their reach Please note that temperature on top of appliance can reach 100 C In case of gas break off the appliance getting blocked it would be necessary to make a new start again see Start U...

Страница 8: ...n preferably in the permanent way by means of a bi polar switch with contacts being at least 3 mm far from each other Please remember the ground conductor must never be cut off In case the connection is made by means of a reverse plug then inform the user that the connection cannot work if the plug is turned upside down N B ROTATE THE PLUG TO GET THE CORRECT CONNECTION THEREFORE THE CORRECT WORKIN...

Страница 9: ...ose to be supplied by the installer G20 G25 Gas Line DIAGRAM TO BE ASSEMBLED BY THE INSTALLER 1 gas tap 2 gas filter 3 vibration free joint ALREADY ASSEMBLED 4 safety double electro valve in class B G30 G31 Gas Line DIAGRAM TO BE ASSEMBLED BY THE INSTALLER 1 gas tap 2 gas filter 3 vibration free joint 4 pressure adjuster ALREADY ASSEMBLED 5 safety double electro valve in class B Pict 5 APPLIANCES ...

Страница 10: ...t made Replace the label by a new one that you ll find in the papers envelope where you ll have to specify the new working gas e Pressure changes depending on the type of gas Type G20 G25 methane lift the safety top from the RP adjusting screw Pict 6 turn the screw until finding the mbar figure on the PV pressure point Pict 6 as stated on the Technical Data table page 1 Type G30 31 butane propane ...

Страница 11: ...the burner is working test the gas pressure value on the manometer and if necessary bring this figure back to the label value by turning either pressure adjusting screw RP Pict 6 of the electro valve with G 20 G 25 gas and on the pressure reducer on the top of the appliance with G 30 31 gas Make sure that gas consumption figure as you now can read from the gas meter is the same as stated in the Te...

Страница 12: ...ng Clear it off Electro valve coil damaged or broken Replace it Electro valve electronic card broken Replace it Starting electrode placed in the wrong way or touching the burner Take it 3 mm away from burner or replace it After the safety time the burner gets blocked again after ignition Phase neuter polarity problem Change power connection or reverse plug socket No ground connection Make ground c...

Страница 13: ...n 15 20 or 25 C always a few degrees over the actual room temperature Now all the functions of the heater start stop become fully automatic to get the desired room temperature To set the burner off just turn room thermostat knob to 0 The air fan 11 Pict 7 has got 2 speeds being operated by the switch 2 Pict 7 The heater can be supplied with a timer upon request 5 Pict 7 that can set working time a...

Страница 14: ...STION FAN 9 GAS PIPE 10 GAS 3 8 NIPPLE 11 FAN 12 ROOM THERMOSTAT BULB 13 INSIDE COMBUSTION AIR BAFFLE 14 BURNER 15 EYE CHECKING HOLE 16 EXCHANGER 17 SHELL 18 BAFFLE 19 TERMINAL PANEL 20 ELECTRONIC BOARD 21 CHIMNEY 22 REAR PANEL 23 AIR COLLECTOR 24 RESET ROOM THERMOSTAT 25 AIR FAN THERMOSTAT Pict 7 W I R I N G D I A G R A M ...

Страница 15: ...M Maximum thermostat EF Smokes pulling fan TF Fan thermostat MV Fan engine TA Room thermostat IMT Line switch DV 2 speed shunt switch To be installed by customer EA Ignition electrode IMT Magneto thermal switch EI Ionization electrode Pict 8 W I R I N G D I A G R A M W I T H T I M E R Commento B1 ...

Страница 16: ...Gas electro valve TM Maximum thermostat BR Atmospheric burner TF Fan thermostat EF Smokes pulling fan TA Room thermostat MV Fan engine IMT Line switch ORP Timer DV 2 speed shunt switch To be installed by customer EA Ignition electrode IMT Magneto thermal switch Pict 9 Commento B2 ...

Страница 17: ...16 Pict 10 ...