9e947
c
11/24/17
7
ViewPoint Touch Screen Installation Instructions
3.3
Wall Mounted Arm
Installation
•
Assembly Arm using the provided hardware
kit, figure 4.
Figure 4: Wall Mounting Arm Details
• Mounting the Arm:
Mount the arm securely to
a wall. Fasteners must tie into the wall fram-
ing. Concrete anchors must be used if mount-
ing to a concrete wall. The holes in the mount-
ing plate are sized for a Ø3/8” [Ø10mm] bolt.
See Figure 5 for installed reference dimen-
sions.
Figure 5
• Power Supply Location:
The power supply
and Ethernet switch should be mounted in-
side the provided enclosure. The power sup-
ply enclosure should then be mounted in the
parlor office near the SmartDairy controller. The
24VDC power wiring and Ethernet cable should
be routed in rigid conduit from the power sup-
ply enclosure out to the junction box in the touch
screen console. See Figure 6. Make sure to leave
extra wire for the possibility to relocate the touch
screen if necessary.
• The 24VDC power wiring
and Ethernet cable
should be routed inside the arm from the power
supply enclosure out to the junction box in the
touch screen console. See figure 6.
Figure 6
• Cables installed correctly
: Make sure both
the ethernet cable and the power supply
cable are ready for installation.
Figure 7: Mounting the arm on the wall