9E-864C
StepMetrix™ Installation Instructions
28
5
Troubleshooting
Table 1: General Troubleshooting Guide.
Symptom Possible
Cause
Action
Communication problem
See Communication Troubleshooting (Table 1a)
ID problem
See ID Troubleshooting (Table 1e)
Dairy PC not running
Verify that the dairy PC has power, is turned on and that the
StepMetrix User Interface Software application has been
running for at least 30 minutes since the last milking.
No SMX data
Power supply problem
See Power Supply Troubleshooting (Table 1f)
Cows walking in groups
Insure that cows are not being hurried over the StepMetrix
sensor module as this may cause them to walk in groups
and generate zero SMX scores.
Load cell errors
See load cell Troubleshooting (Table 1c)
Too many zero SMX
scores
Load cell calibration errors
See StepMetrix Calibration Troubleshooting (Table 1b)
Missing cow data
from network
controller
Network controller communication
problem
See Network Controller Troubleshooting (Table 1d)
StepMetrix controller
connection error
Communication problem
If a controller cannot be accessed from the Setup/Unit
Names or Setup/ Diagnostics menu, or if the following error
message is displayed, see Communication Troubleshooting
(Table 1a)
“StepMetrix is unable to connect to any units at this
time. Please check your cable connections and try
again”.
Battery errors
Battery errors in the diagnostics report
a. Check battery for loose connections.
b. If battery missing or reversed, correct the condition.
c. If battery capacity is less than 50%, replace the
battery. See service section for instructions
StepMetrix or load
cell calibration errors
Load cell Warning or Failure
messages during the StepMetrix
calibration procedure or diagnostics
check.
a. See load cell Troubleshooting (Table 1c)
b. See StepMetrix Calibration Troubleshooting (Table
1b)
StepMetrix Status
Indicator LED is not
flashing green (see
figure 27 for indicator
location)
Verify that the StepMetrix controller is
operational.
Reboot the StepMetrix controller as follows:
a. Press the reset button on the power board. See
Figure 22 for location.
b. Turn off the breaker to the power supply box. Wait
for 30 seconds and turn on the breaker to the
power supply box. The controller should reboot and
the light should begin flashing within 2 minutes.
c. Failure of the light to begin flashing after 5 minutes
may indicate a problem with the hard drive or the
control assembly.
d. If the problem persists, see Power Supply
Troubleshooting Table 1f.
Fan status
Low fan RPM
Fan is failing or not working
a. Look for loose connections
b. If the fan RPM is less than 1750 RPM, replace the
fan. See Section 7.
StepMetrix controller
does not turn on
Discharge resistor is connected to J44
of power board.
Disconnect discharge resistor from J44. See Figure (see
Figure 14b [BM] or 26 [ISO] ) for location.
Содержание StepMetrix
Страница 13: ...14 Wiring diagram label P N 3558769 l864_14 StepMetrix Installation Instructions 9E 864C 13 ...
Страница 14: ...9E 864C StepMetrix Installation Instructions 14 14b The control assembly l864_14b 14a Load cell board l864_14a ...
Страница 20: ...9E 864C StepMetrix Installation Instructions 20 21 Load cell locations l864_24 ...
Страница 21: ...22 ISO ID wiring wiring diagram label P N 3559299 l864_25 StepMetrix Installation Instructions 9E 864C 21 ...
Страница 22: ...9E 864C StepMetrix Installation Instructions 22 24 The control assembly l864 27 23 Load cell board l864_26 ...