![Boumatic StepMetrix Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/boumatic/stepmetrix/stepmetrix_installation-operation-maintenance-and-service-instructions_2796612023.webp)
StepMetrix™ Installation Instructions
9E-864C
23
2.2.7.2
Synchronization of HDX readers
— NOTE ——————————————————————
If there are other HDX (half duplex tag) readers within 500 ft
(150 m) of the StepMetrix ISO ID reader and HDX tags are
used for Ste pMetrix identification, all HDX readers within
500 ft (150 m) must be synchronized with the Ste pMetrix
ISO ID reade r. If the distance b etween the readers is
greater than 500 ft (150 m), or onl y FDX (full duplex) tags
are used for the identification, synchronization of readers is
not necessary.
1. If there are other HD X readers in addition to the
StepMetrix ISO ID read er, connect a two wire
(shielded) cable from SYNC OUT of the StepMetrix ISO
ID reader to the SYNC of the other HDX reader. If there
is a s econd StepMetrix ISO ID read er, connect the
SYNC OUT of the first StepMetrix ISO ID re ader to the
SYNC IN of the second StepMetrix ISO ID reader and
so on until all the readers are connected in the sam e
daisy chain fashion.
2.2.7.3
StepMetrix ISO ID Connections and Tuning
1. Verify that the tuner is connected to the ISO ID control,
as shown in Figure 22.
2. Turn on power to the power supplies
3. The antenna is properly tuned when the green tuning
LED on ISO ID contro l is on. If the red LE D on the left
is on, turn the tuning slug counter-clockwise. If the r ed
LED on the right is o n, turn t he tuning slug clockwise
until the green tuning LED is on (see Figure 22).
2.2.7.4
Communication
For detailed networking instructions, refer to
BouMatic’s Ethernet Co mmunications instructions,
9E-867.
2.3
StepMetrix System Configuration
2.3.1
Installing StepMetrix User Interface Software
The StepMetrix User Inte rface Software should be
installed on the dairy PC. Instructions for installing the
software are found on the installation CD (StepMetrix
User Interface Quick Start).
2.3.2
Unit Names
— NOTE ——————————————————————
•
Steps explained in this s ection must b e performed on
the dairy PC where StepMetrix User Interface program
is installed.
•
Double click the Ste pMetrix icon on the desktop to
begin the program.
•
Setup menu on the soft ware will be i n inactive mode.
Click on the lock icon and enter the password
‘StepMetrix’. The setup menu will be activated.
If more than one StepMetrix system is installed on the
farm; give specific names to those units. Click Setup
and go to Unit Names.
Setup
⇒
Unit Names
1. If there is more than o ne unit, you will see factor y-
installed numbers corresponding to those u nits on th e
left screen. Select a unit and enter the specific name in
the name field and click Tab.
2. Follow the same procedure for other units.
2.3.3
System Setup
1. Click Setup, go to System Setup wizard and enter the
information as directed:
Setup
⇒
Wizards
⇒
System Setup
2.3.4
Dairy Setup
1. After finishing System Setup, click S etup again, go to
the Dairy Setup wizard and enter the i nformation as
directed:
Setup
⇒
Wizards
⇒
System Setup
2.4
StepMetrix Performance Tests
— NOTE ——————————————————————
These steps can be performed from user ’s PC or dea ler’s
PC whichever is convenient.
Following the installation of all StepMetrix
components, perform the following performance tests.
1. Clear the sensor module of any objects. Make sur e
there is no weight on the sensor module.
2. Start the StepMetrix User Interface Program. Go to Unit
Names and click the Zero Platform button:
Setup
⇒
Unit Names
⇒
Zero Platform
2. Go to Diagnostics and select the StepMetrix system to
be checked for performance:
Setup
⇒
Diagnostics
3. If communication between the user’s PC and the
controller is intact, the Di agnostics window will be
displayed. If communicati on has b een lost, the
Diagnostics window will not be displayed. In this cas e,
refer to Table 1a, Communication Troubleshooting.
4. If the Diag nostics window is displayed, there will be
different sections for check ing the status of various
Содержание StepMetrix
Страница 13: ...14 Wiring diagram label P N 3558769 l864_14 StepMetrix Installation Instructions 9E 864C 13 ...
Страница 14: ...9E 864C StepMetrix Installation Instructions 14 14b The control assembly l864_14b 14a Load cell board l864_14a ...
Страница 20: ...9E 864C StepMetrix Installation Instructions 20 21 Load cell locations l864_24 ...
Страница 21: ...22 ISO ID wiring wiring diagram label P N 3559299 l864_25 StepMetrix Installation Instructions 9E 864C 21 ...
Страница 22: ...9E 864C StepMetrix Installation Instructions 22 24 The control assembly l864 27 23 Load cell board l864_26 ...