9E-864C
StepMetrix™ Installation Instructions
18
2. Install rigid PVC conduit (dealer supplied) to protect the
antenna cable from co w traffic and ro ute the cabl e to
the StepMetrix controller antenna (see Figure 18).
2.2.6
Installing the StepMetrix ISO ID Controller
— NOTE ———————————————————
⎯⎯⎯
Route wiring through conduit for protectio n and aesthetic
purposes.
1. Select a location to mount the StepMetrix controller
where the ce nter of the bot tom of the b ox is no mor e
than 70” (1500 mm) from the top of the StepMetrix ISO
ID antenna. The controller should be out of reach of
cow traffic but accessible for service.
2. Using suitable fasteners, mount the controller securely
to a sturd y structure or wall in a way that allo ws the
least amount of vibration to the controller.
3. Connect the flex conduits from the Ste pMetrix ID
antenna and the se nsor module to the bottom of the
controller (see Figure 19).
19.
Installing the StepMetrix™ ISO ID controller
l864_22
Содержание StepMetrix
Страница 13: ...14 Wiring diagram label P N 3558769 l864_14 StepMetrix Installation Instructions 9E 864C 13 ...
Страница 14: ...9E 864C StepMetrix Installation Instructions 14 14b The control assembly l864_14b 14a Load cell board l864_14a ...
Страница 20: ...9E 864C StepMetrix Installation Instructions 20 21 Load cell locations l864_24 ...
Страница 21: ...22 ISO ID wiring wiring diagram label P N 3559299 l864_25 StepMetrix Installation Instructions 9E 864C 21 ...
Страница 22: ...9E 864C StepMetrix Installation Instructions 22 24 The control assembly l864 27 23 Load cell board l864_26 ...