background image

 
OPERATING INSTRUCTIONS 

 

 

 

Place the 

B8572

 instrument on table top or 

flat surface, test button a if low battery 
symbol appears , replace batteries. 

 

Take 5lbs weights from case (use care) 

 

Plug red/black test leads into test weights 

 

Plug other end of leads into 

B8572

 

 

Accessories: 

B8565/20 

(one 20’ test lead)  

(For testing surface to ground on floors) 
 

TESTING: 

 

Types of testing as specified in ESD-S4.1 

 

1.

 

Periodic testing on installed static safe 
workstations. 

2.

 

Qualification of workstation materials 

3.

 

Performance of materials 

4.

 

 

 

PERIODIC TESTING OF INSTALLED 

PRODUCTS 

Measure RTG (Resistance to Ground)

 

 

Remove items from surface to be tested 

 

Remove ESD sensitive devices 

 

Clip one end of test lead from B8572 to 
grounded point (see fig 2.1) 

 

Use one 5lb electrode on other test lead to 
surface to be tested and push green button 

 
 
 
 
 
 
 
 
 
 
 

TESTING FLOORS 

 

 

Place one 5lb electrode of floor surface and with 

B8565/20 

20’

 

lead connect to known  ground point.  

(check with your facility staff) 

 
 

 

 
 
Note: 

ESD 7.1 is designed to measure floor materials 

with resistance of 2.5 x 10

4

 to 1.0 x 10

11  

ohms. 

 

Note:  

ESD-S4.1 suggests that a static control surface 

in the test range of 1 x 10

to 1.0 x 10

10  

ohms is 

acceptable. 
 

 

QUALIFICATION OF INSTALLED 

STATIC SAFE SURFACE RT

T

 

 

Measurements of resistance of Top to Top  
and resistance point to point  are the same. 
 

 

Place both 5lb electrodes on surface to be tested.  

 

 

Place no closer than 2” from edge of  surface to be 
tested. 

 

 

Place no closer than 3” from any groundable point. 
(snaps are a groundable point). 

 

 

Place in the center of mat area it would be area 
most worn. (about 10” apart) 

 

 

For 

RTG

 Fig 2.1 place one lead with insulated plug 

to groundable point. 

 
 

 
 
 
 
 
 
 
 
 

 
 
 
REPORTING AND USING TEST RESULTS 

 
Different standards have different requirements please 
review the standards that you are testing too. 

 
Per ESD 4.1

 (work surfaces) 

RTG maximum and minimum values                  
measured for resistance-to ground 
 RTG maximum and minimum values measured for 
point-to-point resistance in ohms. 
 

Per ESD 7.1

 (floors) 

 

 

RTG all values in ohms for resistance to ground 

 

RTT all values in ohms for point-to-point resistance. 

 

Voltage levels tested 

 

<10

6   

@ 10 volts 

 

>10

6   

@ 100 volts 

 

Note: Temperature & Humidity 

 

Test dates (work surfaces) quantity see ESD 
handbook TR 20.20 phg/ 5.3.1.3  

Fig 2.1 

10” apart 

Test leads 

Fig 2.2 

Fig. 2.3 

To known 
ground 

RTG

 Test 

 

Mat surface 

Mat surface 

RTT test 

Always clean bottom of electrodes with alcohol pads 

Always clean mat surface with approved cleaner 

Отзывы: