19
Set up the wire feed unit as per section
“Set up Wire Feed Unit”. Ref page 40
3
MIG MANUAL SETUP (GASLESS) CONTINUE
Note:
Pictures may vary from your machine model
OFF
Plug the machine 10Amp input power lead into
the wall socket, ensuring that the power
switch on the machine is in the OFF position.
1
Roller Groove
V Groove - Mild Steel
U Groove - Aluminium
V-knurled - Gasless Wire
Drive roller
size (mm)
Install Euro connect MIG torch over the
protruding wire, line up the spring connectors
and screw the Euro connector nut up firmly.
4
DCEN - GASLESS
DCEP - GAS
SETTING MACHINE POLARITY
Ensure the polarity switching cable is
plug into negative output connection
socket for gasless welding
5
Fit the Earth lead Dinse Plug to the positive
terminal for gasless welding and then connect
earth clamp to the work piece ensuring that
the clamp makes good contact with bare metal.
6
Continue from MIG manual GAS set up
page 17; step 9 to 14.
8
Note:
It is advisable to run a few test welds using scrap
or offcut materials, in order to tune the machine
to the correct settings prior to welding the job.
Switch the machine ON using the mains
power switch. Wait a few seconds whilst
the machine powers up.
7
ON
Open wire feed side panel & install GASLESS
wire into machine ensuring the drive roller is
matched to the wire size and type. Refer to
Machine Drive Roller Size Guide on page 41
Note: Wire to roll from under spool into the
wire guide inlet tube
2