Installation Guide
and Users Manual
Wall Mount Range Hood
IMPORTANT:
Read and save these instructions.
NOTICE:
Installer:
Leave this guide with the homeowner
Homeowner:
Keep this guide for future reference
Supreme Pro 30" Wall Mount
Страница 1: ... Guide and Users Manual Wall Mount Range Hood IMPORTANT Read and save these instructions NOTICE Installer Leave this guide with the homeowner Homeowner Keep this guide for future reference Supreme Pro 30 Wall Mount ...
Страница 2: ...rities Before servicing or cleaning unit switch power OFF at service panel and lock service panel to pre vent power from being switched ON accidentally Clean grease laden surfaces frequently To reduce the risk of fire and to disperse air properly make sure to vent air outside DO NOT vent exhaust into spaces between walls crawl spaces ceiling attics or garages Ducted fans MUST always be vented to t...
Страница 3: ...go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT or dial your local emergency service immediately DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result Use an extinguisher ONLY if You know you have a Class A B C extinguisher and you already know how to operate it The fire is small and contained in the area where it is started The fire department is being...
Страница 4: ...t heights clearance 5 6 Calculating vent system length 6 Venting methods ductless conversion 7 Charcoal filters electrical requirements 8 Preparation 9 Installation 10 11 Range hood operations 12 13 Wiring diagram measurements 14 16 USE AND CARE Troubleshooting 17 Use and care information 18 Specifications 18 MAINTENANCE Cleaning 19 Replacing filter light bulb 19 WARRANTY Coverage exceptions 20 Di...
Страница 5: ...llation Guide and Users Manual 1 Set 5mm x 16mm Screw with Washer 4 Set 4mm x 16mm Tapping Screw 6 Pcs 4mm x 10mm Tapping Screw 16 Pcs Optional Toggle Bolt with Tapping Screw for Air Diverter 2 Set Optional Screw for Charcoal Filter 3 Pcs Lower standard chimney Upper standard chimney Flappers Parts supplied Range Hood vary with model Stainless Steel Baffle Filter s Chimney Mounting Bracket Grease ...
Страница 6: ... coun 2 tertop stove recommend 28 to 31 Distance between the countertop stove 3 to the range hood Height of hood and duct cover 4 For the most efficient quiet operation A distance of 28 to 31 is recommended between stove top and the bottom of range hood It is recommended that the range hood be vented vertically through the roof through 6 15 2 cm or bigger round metal aluminum vent work The size of...
Страница 7: ...e no higher than 31 inch It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and will loose its performance and efficiency If available also refer to stove top manufacturer s height clearance requirements and recommended hood mounting height above range Due to differen...
Страница 8: ...version is intended for applications where an exhaust duct work is not possible to be installed When converted the hood functions as a purifying hood rather than an exhaust hood Fumes and exhaust from cooking is drawn and filtered by a set of charcoal filters The air is then purified and re circulated back within the home We recommend to ALWAYS exhaust air outside of the home by employing existing...
Страница 9: ...opper wire plug only Always use plug provided If not possible connect three wires ac cording to its color black to hot white to neutral and green to ground to house wires and cap with wire connectors Wire sizes copper wire only and connections must conform with the rating of the appliance as specified on the model serial rating label Wire sizes must conform to the requirements of the National Elec...
Страница 10: ...pport mounting bracket holes vent cutout if used and power supply cable cutout 4 on the ceiling Use drill and saber saw or keyhole saw to cut openings for power supply cable and vent see Venting Methods and Electrical requirements Pages 7 8 If venting to the outside install vent system see 5 Venting Methods Page 7 Use caulking to seal exterior wall or roof openings Disconnect main electrical suppl...
Страница 11: ...ended Attach the hood mounting bracket to the back of the hood with four screws as shown in Figure 1 3 Align hood mounting bracket to the screws on the wall and hook hood into place as shown in Figure 2 and 4 Figure 3 Tighten screws to secure hood to the wall CAUTION Make certain the range hood is secure before releasing For safety purpose pre drilled mounting holes are provided through the back o...
Страница 12: ... Figure 9 5 To avoid scratching the chimney extend the upper chimney slowly and carefully to the chimney mounting 10 bracket and tigten screws as shown in Figure 6 To install stainless steel baffle filters refer to Figure 7 for the following five steps 11 Angle baffle filter toward back of hood Push baffle filter up until almost level Slide forward into recess behind the front of hood Lower baffle...
Страница 13: ...lower motor running time starts to accumulate when it first rotates when the running time reached 30 hours the Cleaning Reminder Indicator C flashes and reminds user to clean the range hood After cleaning the filter and when the motor is not in use press and hold Increase Value button over 3 seconds to reset the timer Please note that turning off the system will not reset the Power On Elapsed Time...
Страница 14: ...Adjusting the light Press Light button once to turn on the lights and once again to turn off the lights While the lights are off press and hold Light button for over 3 seconds to dim the lights from high to low Level of brightness will be stored in system s memory CAUTION DO NOT touch the lights until switched OFFand cooled Note Light settings are independent from other settings including power of...
Страница 15: ...Page 14 Wiring Diagram 4 Speed Wiring Diagrams Wiring Diagram 6 Speed NOTE Wiring Diagrams shown above with GU10 light configuration A transformer is required for MR16 Lights ...
Страница 16: ...t exhaust Re circulating kit not shown Duct work and electric wiring region Note Type A anchors are designed for dry wall Not to be used with any other types of walls Mounting Bracket A B C A B C Hex Key Qty 1 PCS Optional with glass canopy Glass Canopy Screw Qty 4 PCS Optional with glass canopy Qty 6 PCS For sheet rock only A Qty 6 PCS B Qty 4 to 8 PCS Vary with model C Air Movement Direction ...
Страница 17: ...Page 16 Measurements and Diagrams Continued All inch measurements are converted from millimeters thus inch measurements are estimated AP238 PSL Overall AP238 PSZ AP238 PSF AP238 PSD ...
Страница 18: ...ir cular flapper is not installed correctly or opening properly A tight mesh on a side wall cap unit might also cause restriction to the air flow The lights work but the blower is not spinning at all 4 is stuck or is rattling The blower might be jammed or scraping the bot tom due to shipping damage Please contact us im mediately The hood is not venting out properly 5 Make sure the distance between...
Страница 19: ...ting blowers could catch on to hair fingers and loose clothing NEVER dispose cigarette ashes ignitable substances or any foreign objects into blowers NEVER leave cooking unattended When frying oil in the pan can easily overheat and catch fire The risk of self combustion is higher when the oil has been used several times NEVER cook on open flames under the range hood Check deep fryers during use Su...
Страница 20: ... contact with stainless steel for extended periods Many of these compounds contain chemicals which may be harmful Rinse with water after ex posure and wipe dry with a clean cloth Cleaning Stainless Steel Baffle Filters IMPORTANT Drain oil from oil containers before oil and residue overflow The metal filters fitted by the factory are intended to filter out residue and grease from cooking It need no...
Страница 21: ...nsumable parts such as light bulbs metal and charcoal filters The natural wear of finish and wear due to improper maintenance use of corrosive and abrasive cleaning products pads and oven cleaner products Chips dents or cracks due to abuse misuse freight damage or improper installation Damage of product caused by accident fire floods or act of God The manufacturer and or distributor reseller is no...
Страница 22: ...ing fee of 15 will be charged for all approved return s Exchanges or returns may not be accepted if any packaging is missing Make sure to inspect the hood for damages and defects before installation Appearance flaws of the hood found after installation and not affecting hood performance is not covered under our warranty for returns or exchang es Service visits not covered under warranty will carry...
Страница 23: ...Bossino Cook Till Your Hearts Content www bossino com ...