Installation Guide
and Users Manual
Wall Mount Range Hood
IMPORTANT:
Read and save these instructions.
NOTICE:
Installer:
Leave this guide with the homeowner
Homeowner:
Keep this guide for future reference
Rev. 3065u.1b
Страница 1: ...lation Guide and Users Manual Wall Mount Range Hood IMPORTANT Read and save these instructions NOTICE Installer Leave this guide with the homeowner Homeowner Keep this guide for future reference Rev 3065u 1b ...
Страница 2: ...rities Before servicing or cleaning unit switch power OFF at service panel and lock service panel to pre vent power from being switched ON accidentally Clean grease laden surfaces frequently To reduce the risk of fire and to disperse air properly make sure to vent air outside DO NOT vent exhaust into spaces between walls crawl spaces ceiling attics or garages Ducted fans MUST always be vented to t...
Страница 3: ...ny bodily injuries whether caused directly or indirectly by the range hood Clean ventilating fan frequently Always use appropriate cookware and utensils size Always use cookware appropriate for the size of the surface element To reduce the risk of injury to persons in the event of a stove top grease fire SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn OFF the burner BE...
Страница 4: ...Installation 10 11 Range hood operations 12 13 USE AND CARE Troubleshooting 14 Use and care information 15 Specifications 15 Measurements Diagrams 16 21 MAINTENANCE Cleaning 22 Replacing the filter light bulb 22 WARRANTY Coverage exceptions 23 Disclaimer Contact Us 24 Tools needed Page 3 Level Flat blade and Phillips screwdrivers Powered screwdriver or drill Measuring tape Utility knife Marker or ...
Страница 5: ...nly Qty 2 PCS 30 in models Qty 3 PCS 36 in models Chimney mounting Bracket Qty 6 PCS Qty 4 PCS Qty 4 PCS Lower Chimney Qty 2 PCS 30 in models Qty 3 PCS 36 in models Qty 4 PCS 30 in models Qty 6 PCS 36 in models Upper Chimney Range Hood Baffle Filters ...
Страница 6: ...e vented vertically through the roof through 6 15 3 cm or bigger round metal aluminum vent work The size of the vent should be uniform Use no more than three 90 elbows Make sure there is a minimum of 24 61 cm of straight vent between the elbows if more than one elbow is used DO NOT install two elbows together The length of vent system and number of elbows should be kept to a minimum to pro vide ef...
Страница 7: ...uld be no higher than 30 inch It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and will loose its performance and efficiency If available also refer to stove top manufacturer s height clearance requirements and recommended hood mounting height above range Due to dif...
Страница 8: ...r terminate duct work into spaces between walls crawl spaces ceiling attics or garages All exhaust must be ducted to the outside Use metal aluminum duct work only Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape Use caulking to seal exterior wall or roof opening around the cap Vertical roof venting Roof cap Option 2 Side wall cap Horizontal...
Страница 9: ...T Save this Installation Guide for electrical inspector s use The range hood must be connected with copper wire plug only The range hood should be connected directly to the fused disconnect or circuit breaker box through flexible armored or non metallic sheathed copper cable A U L or C S A listed strain relief must be provided at each end of the power supply cable Wire sizes copper wire only and c...
Страница 10: ...talling Mark the locations of the support mounting bracket holes vent cutout if used and power supply cable cutout on the ceiling Use drill and saber saw or keyhole saw to cut openings for power supply cable and vent see Venting requirements and Electrical requirements Pages 6 8 If venting to the outside install vent system see Venting Requirements Page 5 Use caulking to seal exterior wall or roof...
Страница 11: ...3 3 Align hood mounting bracket to the screws on the wall and hook hood into place as shown in Figure 4 and 4 Figure 5 Tighten screws to secure hood to the wall CAUTION Make certain the range hood is secure before releasing For safety purpose pre drilled mounting holes are provided through the back of the hood For a more secure 5 installation use as many mounting holes as needed to secure from the...
Страница 12: ...rews to secure the lower chim 9 ney to the range hood as shown in Figure 8 To avoid scratching the chimney extend the upper chimney 10 slowly and carefully to the chimney mounting bracket and tigten screws as shown in Figure 9 To install baffle filters refer to Figure 10 for the following three 11 steps Angle baffle filter toward back of hood Slide the knob toward the metal filter handle and push ...
Страница 13: ...tor is running the heat sensor evaluates surrounding temperature and increase the blower to the top speed automatically when reached the user defined temperature The blower speed de creases by 1 level in every 20 seconds when the surrounding temperature is below the user defined temperature and back to the original speed level Activating Normal Blower Function While the range hood is off press Inc...
Страница 14: ...off timer by pressing Increase or Decrease button minimum 1 minute to maximum 15 minutes Timer beings to countdown immediately when it reaches 0 the blower will shut off Remote Control Sensor Remote control sensor receives infrared IR signal from the remote control The maximum distance for IR data transmission is 3 meter and requires direct line of sight The transmission distance may vary depend i...
Страница 15: ...mple 7 duct over 6 hole and loosely secured Check if duct is clogged or if damper unit half cir cular flapper is not installed correctly or opening properly A tight mesh on a side wall cap unit might also cause restriction to the air flow The lights work but the blower is not spinning at all 4 is stuck or is rattling The blower might be jammed or scraping the bot tom due to shipping damage Please ...
Страница 16: ... replaced immediately DO NOT operate blowers when filters are removed Never disassemble parts to clean without proper instruc tions Disassembly is recommended to be performed by qualified personnel only Read and understand all instructions and warnings in this manual before proceeding Page 15 Specifications3 Body Design Seamless Stainless Steel Satin Finish Glossy Piano Black Finish Power Rating 2...
Страница 17: ...w C D Upper support frame Range hood Round duct exhaust Chimney mounting bracket A Air Movement Direction Upper chimney C D Hood mounting bracket B Qty 4 PCS For sheet rock only Qty 6 PCS Qty 4 PCS Qty 4 PCS C D B A Back of the range hood A Page 16 ...
Страница 18: ...All measurements in parenthesis are in millimeter All inch measurements are converted from millimeters thus inch measurements are estimated Overall Page 17 ...
Страница 19: ...Page 18 Overall without Chiminey All measurements in parenthesis are in millimeter All inch measurements are converted from millimeters thus inch measurements are estimated ...
Страница 20: ...Page 19 Circuit Diagram Hood mounting Bracket ...
Страница 21: ... Handle 4 Chimney Mounting Bracket 16 Electrical Box Cover 5 Hood Mounting Bracket 17 Electrical Box Base 6 Power Cable 18 Halogen Light Transformer 7 Safety Screen 19 Electrical Panel 8 Locknut 20 Control Panel Assembly Panel 9 Squirrel Cage 21 Hood Casing 10 Air Chamber 22 Baffle Filter 30 in 2pcs 36 in 3pcs 11 Motor 23 Baffle Filter Handle Screw 12 Halogen Light 24 Baffle Filter Handle ...
Страница 22: ...Air Chamber 5 Safety Screen 3 Squirrel Cage Electrical Assembly No Description No Description 1 Screws 3 16 x 3 8 6 Electrical Panel 2 Electrical Box Cover 7 Capacitor 3 Processor Board 8 Screws 3 16 x 3 8 4 Screws 3 16 x 3 8 9 Halogen Light Transformer 5 Electrical Box Base ...
Страница 23: ...ool or steel brushes Small bits of steel may adhere to the surface and cause rusting DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless steel for extended periods Many of these compounds contain chemicals which may be harmful Rinse with water after ex posure and wipe dry with a clean cloth Cleaning Aluminum Grease Filter Stainless Steel Fil...
Страница 24: ...nsumable parts such as light bulbs metal and charcoal filters The natural wear of finish and wear due to improper maintenance use of corrosive and abrasive cleaning products pads and oven cleaner products Chips dents or cracks due to abuse misuse freight damage or improper installation Damage of product caused by accident fire floods or act of God The manufacturer and or distributor reseller is no...
Страница 25: ...ing fee of 15 will be charged for all approved return s Exchanges or returns may not be accepted if any packaging is missing Make sure to inspect the hood for damages and defects before installation Appearance flaws of the hood found after installation and not affecting hood performance is not covered under our warranty for returns or exchang es Service visits not covered under warranty will carry...
Страница 26: ......