![Boss MS-3 Скачать руководство пользователя страница 32](http://html.mh-extra.com/html/boss/ms-3/ms-3_parameter-manual_2793543032.webp)
32
EFFECT
Parameter
Value
Explanation
FUNC
(FUNCTION)
BANK+
Switches to the next bank number.
BANK-
Switches to the previous bank
number.
PATCH+
Switches to the next patch number.
PATCH-
Switches to the previous patch
number.
MODE
(SOURCE MODE)
Specifies how the value changes when you operate the
footswitch.
MOMENT
The normal state is Off
(minimum value), with the switch
On (maximum value) only while the
footswitch is depressed.
TOGGLE
The setting is toggled On
(maximum value) or Off
(minimum value) with each press of
the footswitch.
ACTION
OFF
0
ON,
ON
0
OFF
<When MODE is set to MOMENT>
OFF
0
ON:
On while the switch is held down,
and off when it is not held down.
ON
0
OFF:
Off while the switch is held down,
and on when it is not held down.
ASSIGN 1–8
For each parameter, you can specify, in detail, which controller will
control which parameter.
You can make eight settings for each patch.
Parameter
Value
Explanation
ASSIGN
OFF, ON
Turns the ASSIGN 1–8 on/off.
* If you set SOURCE to WAVE, leave
ASSIGN turned OFF until you
finish making the settings. If this
is left ON, parameters might be
switched unintentionally while
you make settings.
SOURCE
Specifies the controller (source).
NUM1
Assigns number switch [1] when in
manual mode.
NUM2
Assigns number switch [2] when in
manual mode.
NUM3
Assigns number switch [3] when in
manual mode.
NUM4
Assigns number switch [4] when in
manual mode.
M/M
(MEMORY/MANUAL)
Assigns the [MEMORY/MANUAL]
switch.
CURNUM
(CURRENT NUMBER)
Assigns the currently selected
number switch when in memory
mode.
EXP1
Assigns the expression pedal
connected to EXP 1 of the CTL IN
jacks.
EXP2
Assigns the expression pedal
connected to EXP 2 of the CTL IN
jacks.
CTL IN1
Assigns the footswitch connected
to CTL 1 of the CTL IN jacks.
CTL IN2
Assigns the footswitch connected
to CTL 2 of the CTL IN jacks.
CTL IN3
Assigns the footswitch connected
to CTL 3 of the CTL IN jacks.
CTL IN4
Assigns the footswitch connected
to CTL 4 of the CTL IN jacks.
INT
(INTERNAL PEDAL)
Assigns the
internal pedal.
Refer to “Virtual
WAV (WAVE PEDAL)
Assigns the
wave pedal.
MODE
(SOURCE MODE)
Specifies how the value changes when you operate the
controller.
MOMENT
The normal state is Off
(minimum value), with the switch
On (maximum value) only while the
control is being operated.
TOGGLE
The setting is toggled On
(maximum value) or Off
(minimum value) with each time
control is operated.
CATEGORY
(TARGET CATEGORY)
Selects the parameter to be changed.
Refer to “Target List” (p. 34).
TARGET
MIN
(TARGET MIN)
Sets the minimum value for the range in which the
parameter can change. The value differs depending on the
parameter assigned for TARGET parameter.
MAX
(TARGET MAX)
Sets the maximum value for the range in which the
parameter can change. The value differs depending on the
parameter assigned for TARGET parameter.
ACT.LOW
(ACT RANGE LOW)
0–126
Sets the controllable range for
target parameters within the
source’s operational range. Target
parameters are controlled within
the range set with ACT.LOW and
ACT.HIGH. You should normally set
ACT.LOW to 0 and ACT.HIGH to 127.
ACT.HIGH
(ACT RANGE HIGH)
1–127