![Boss MS-3 Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/boss/ms-3/ms-3_parameter-manual_2793543027.webp)
27
EFFECT
OUTPUT (OUTPUT SETTING)
These are the settings for OUTPUT SELECT, CTL OUT1, and CTL OUT2.
Parameter
Value
Explanation
OUT SEL.
(OUTPUT SELECT)
Selects how the sound is output to the OUTPUT L/MONO jack
and the R jack.
L
Output the sound only to the OUTPUT L/MONO
jack.
* If the OUTPUT R jack is not connected, the
level will be lower.
* If the PREFERENCE setting OUTPUT SEL is set
to SYSTEM, this is shown as L (SYS).
R
Output the sound only to the OUTPUT R jack.
* If the OUTPUT L/MONO jack is not connected,
the level will be lower.
* If the PREFERENCE setting OUTPUT SEL is set
to SYSTEM, this is shown as R (SYS).
L+R
The same sound is output from the OUTPUT L/
MONO jack and the OUTPUT R jack.
* The stereo sensation of the effect is lost.
* If the PREFERENCE setting OUTPUT SEL is set
to SYSTEM, this is shown as L+R (SYS).
STEREO
* If the PREFERENCE setting OUTPUT SEL is set
to SYSTEM, this is shown as ST (SYS).
CTLOUT1
Specify the control signals that are sent from the CTL 1 of the
CTL OUT jack when you switch patches.
The available control signals depend on the MENU item CTL
OUT MODE SETTING (p. 40) setting.
For LAT
OFF
Sends “off.”
Guitar amp
(Channel switching jack)
MS-3
(CTL OUT CTL 1 jack)
ON
Sends “on.”
Guitar amp
(Channel switching jack)
MS-3
(CTL OUT CTL 1 jack)
Parameter
Value
Explanation
CTLOUT1
For PLS, INV
OFF
Sends a short (100 ms) pulse when changing
between “off” and “on.”
* If the display of the MS-3 differs from the
state of the connected equipment, switch the
state of the connected equipment.
ON
If the MENU item CTL OUT MODE SETTING is TAP2, TAP3,
or TAP4
OFF
Sends nothing.
TAP: –
Sends tempo at the interval of the specified
note value according to the MASTER BPM
value.
* Depending on the MASTER BPM setting,
there are cases in which this cannot be sent.
TAP: 40–250 Sends the specified tempo (
¸
=)
CTLOUT2
Specify the control signals that are sent from the CTL 2 of the
CTL OUT jack when you switch patches.
The available control signals depend on the MENU item CTL
OUT MODE SETTING (p. 40) setting.
For LAT
OFF
Sends “off.”
Guitar amp
(Channel switching jack)
MS-3
(CTL OUT CTL 2 jack)
ON
Sends “on.”
Guitar amp
(Channel switching jack)
MS-3
(CTL OUT CTL 2 jack)
For PLS, INV
OFF
Sends a short (100 ms) pulse when changing
between “off” and “on.”
* If the display of the MS-3 differs from the
state of the connected equipment, switch the
state of the connected equipment.
ON
If the MENU item CTL OUT MODE SETTING is TAP2, TAP3,
or TAP4
OFF
Sends nothing.
TAP: –
Sends tempo at the interval of the specified
note value according to the MASTER BPM
value.
* Depending on the MASTER BPM setting,
there are cases in which this cannot be sent.
TAP: 40–250 Sends the specified tempo (
¸
=)