PREMIUM FULL INVERTER HEAT PUMP

Содержание Celsius Platinum PL13HP

Страница 1: ...Celsius Platinum InverterHeat Pump Installation UserManual 1 Installation User Manual PREMIUM FULL INVERTER HEAT PUMP ...

Страница 2: ...tions 7 10 2 1 Notice before using 7 2 2 Operation Instructions 7 9 2 3 Maintenance and winterising 10 3 Technical Specification 11 FOR INSTALLERSAND PROFESSIONALS 4 Transportation 12 5 Installation and maintenance 13 20 5 1 Notice before installation 13 5 2 Installation Instructions 14 17 5 3 Trial afterInstallation 20 5 4 Maintenance and winterising 20 6 Trouble Shooting Guide 21 7 ErrorCodes 22...

Страница 3: ...7O C 43O C Temperature Setting Heating 18O C 40O C Cooling 12O C 35O C The heat pump will have ideal performance in the operation range Air 15O C 25O C The heat pump has two modes Smart and Silence They have different advantages underdifferent conditions Mode Recommendation Advantages Smart Mode As standard Heating capacity 20 to 100 capacity Intelligent optimization Fast heating Silence Mode Use ...

Страница 4: ...poweris recovered the heat pump will restart automatically The heat pump can only be used with pool water It can NEVER be used to heat orcool other flammable orturbid liquid When moving the heat pump do not lift the waterunion This will damage the titanium heat exchanger Do not obstruct the airinlet oroutlet ofthe heat pump 1 4 1 1 4 2 1 4 3 ...

Страница 5: ...may be reduced oreven stopped To avoid fire hazards do not store oruse combustible gas orliquids such as thinners paints orfuels nearthe heat pump Ifyou detect any abnormal noises odours smoke orleaks from the heat pump immediately switch offthe powersupply and contact yourlocal dealer Do not attempt to repairthe heat pump yourself 1 4 4 1 4 5 1 4 6 ...

Страница 6: ... ofthe reach ofchildren 1 4 7 Please disconnect the heat pump from the powersupply during electrical storms 1 4 8 Please note that following codes are not failures 1 4 9 Codes No waterflow E3 Anti freezing reminder Ed Out ofthe operating range Eb Insufficient waterflow orpump blocked E6 Powerabnormal E5 ...

Страница 7: ...ump before the water pump Check for any water leakage in connecting pipework then turn on the power supply press the ON OFF button ofthe heat pump and set desired temperature Symbol Designation Operation PowerON OFF PowerOn Off Unlock Mode 1 Press it for3 seconds to unlock lock screen 2 Afterscreen is unlocked press it to select mode Auto 12 40O C Heating 18 40O C Cooling 12 30O C Speed SelectTurb...

Страница 8: ...l be dark and 0 will be displayed b All otherbuttons are only functional afterthe screen is unlocked a Press for3 seconds to unlock screen The screen will illuminate Symbol Operation Heating Heating capacity percentage Real time powerconsumption display Wifi connection Waterinlet Wateroutlet M 80 KW 0 68 WaterInlet Temperature Turbo Smart Silence Mode WaterOutlet Temperature 1 2 ...

Страница 9: ...nce mode the screen shows Press again the screen shows and return to Smart mode 5 6 Defrosting Wifi Setting Auto Defrosting When heat pump is defrosting will be flashing Afterdefrosting will stop flashing Compulsory Defrosting When heat pump is heating press and togetherfor5 seconds to start compulsory defrosting and will be flashing Afterdefrosting will stop flashing Note Compulsorydefrosting int...

Страница 10: ... In climates where the winter season reaches sub zero temperatures please disconnect from power supply and drain water out ofthe heat pump When using the heat pump under 2 C make sure there is always waterflow Check bolts cables and connections regularly Every three months spray a surface insecticide on the surfaces around the unit to prevent and and insect ingress 1 2 3 IMPORTANT Unscrewthe water...

Страница 11: ...3 4 6 7 8 4 6 7 8 4 9 7 8 COP at 50 capacity 6 5 6 6 6 8 6 8 6 8 Sound pressure at 1m dBA 38 6 46 9 42 0 47 7 42 9 50 8 40 8 51 2 43 3 51 9 Sound pressure of 50 capacity at 1m dBA 41 3 43 7 44 5 44 4 46 4 Sound pressure at 10m dBA 18 6 26 9 22 0 27 7 22 90 30 8 20 8 31 2 25 3 31 9 Power supply 230V 1 Ph 50Hz Advised water flux litre min 50 66 66 100 108 141 133 166 166 200 Fittings Australian 50mm...

Страница 12: ...tion UserManual 12 4 TRANSPORTATION When storing ormoving the heat pump please ensure the unit remains in an upright position at all times When moving the heat pump do not lift the waterunion This will damage the titanium heat exchanger 4 1 4 2 ...

Страница 13: ... It is strongly advised that the heat pump is installed by a professional Unqualified installations may result in damage to the heat pump and orsafety risks to the user 5 1 NOTICE BEFORE INSTALLATION Plumbing connections must be made with solid PVC pipe Usage offlexible PVC pipe is not recommended 5 1 1 ...

Страница 14: ...the heat loss in the pipes As the pipes are mostly underground the heat loss is lowfordistances up to 30m 15m from and to the heat pump 30m in total unless the ground is wet or the groundwaterlevel is high Arough estimate ofthe heat loss per30m is 0 6 kWh 2 000 BTU forevery 5 C difference between the watertemperature in the pool and the temperature ofthe soil surrounding the pipe This increases th...

Страница 15: ...itation and automatic dosing systems must be plumbed afterthe heat pump Acheck valve must be installed between the sanitation automatic dosing system and the heat pump to prevent chemicals returning to the heat pump Failure to observe this instruction willvoid the warranty INDEPENDENT SYSTEM IN LINE SYSTEM ...

Страница 16: ...Celsius Platinum InverterHeat Pump Installation UserManual 16 ADJUSTING THE BYPASS A B ...

Страница 17: ...Position B until the display error code of E6 disappears Once the message clears the default display is the current watertemperature Starting sequence will now begin 1 2 3 ATTENTION Operation without a bypass orwith improperbypass adjustment may result in suboptimal heat pump operation and possible damage to the heat pump Failure to observe this instruction willvoid the warranty Bypass Installatio...

Страница 18: ...ensation will occur and drain from the bottom ofthe unit This is completely normal However consideration should be made for how to drain the condensation away Drainage nozzle and pipe are supplied Connect to appropriate power supply The voltage should comply with the rated voltage ofthe unit Earth the machine well Wiring must be handled by a professional technician according to the circuit diagram...

Страница 19: ...50Hz 1 2 Distribution Box Customer prepare Power Cord Swimming Pool Heat Pump Wiring Board Power Supply 240V 50Hz Earthing Breaker Fuse Distribution Box Customer prepare Power Supply 380V 50Hz Earthing Breaker Fuse Power Cord Swimming Pool Heat Pump Wiring Board ATTENTION Forthe detailed wiring diagram please refertoAppendix 1 ...

Страница 20: ...art the water pump before the heat pump and turn offthe heat pump before the water pump for long life circle Check the electric wiring according to the electrical wiring diagram and earthing connection The user should start the water pump and check for any leakage ofwater power on and press the ON OFF button ofthe heat pump and set desired temperature in the thermostat Make sure that the main powe...

Страница 21: ...ible blockage 4 Checkflow switch and PCB wiring technician only E5 Power voltage supply outside acceptable operating range Engage electrician to confirm powersupply referto technical specifications E6 Excessive temperature differential between inlet and outlet water insufficient water flow protection Ensure waterflowthrough circulating pump filtration system 1 a Ensure circulating pump is primed i...

Страница 22: ...P4 Evaporator coil pipe temp sensor failure 12 P5 Gas return temp sensor failure 13 P6 Cooling coil pipe temp sensor failure 14 P7 Ambient temp sensor failure 15 P8 Cooling plate sensor failure 16 P9 Current sensor failure 17 PA Restart memory failure 18 F1 Compressor drive module failure 19 F2 PFC module failure 20 F3 Compressor start failure 21 F4 Compressor running failure 22 F5 Inverter board ...

Страница 23: ... Platinum InverterHeat Pump Installation UserManual 23 8 WIFI SETTING App Download Account Registration 1 2 iPhone please download from Android mobile please download from Registration by mobile number email 1 ...

Страница 24: ...Celsius Platinum InverterHeat Pump Installation UserManual 24 WIFI SETTING Mobile numberregistration 2 Create family Please set family name and choose the room ofdevice 3 ...

Страница 25: ...ing display on the screen onceWifi connection success C D Ifconnect fails please make sure yournetwork name and password is correct And yourrouter mobile phone and device are as close as possible Wifi rebinding WhenWifi password changes ornetwork configuration changes Press for10 seconds will be flashing slowly for60 seconds Then will be off The original binding will be removed Follow step above f...

Страница 26: ...ual 26 WIFI SETTING Operation Forheat pump with Heating function only 5 More share devices Indicate the status ofheating Current swimming pool water temperature The setting temperature Timer Select Smart Silence Mode ON OFF Heating capacity Select CO C FO C ...

Страница 27: ...stallation UserManual 27 WIFI SETTING Share devices to yourfamily members Afterbinding ifyourfamily members also want to control the device Please let yourfamily members registertheAPP first and then the administratorcan operate as below 6 ...

Страница 28: ...lsius Platinum InverterHeat Pump Installation UserManual 28 WIFI SETTING Then yourfamily members can log in as below NOTE The weatherforecast is just forreference APP is subject to updating without notice ...

Страница 29: ...Celsius Platinum InverterHeat Pump Installation UserManual 29 Scan to access Boss Polymer Technologies Pty Ltd Terms and Conditions of Trade sales bosssolar com au www bosssolar com au 1300 786 489 ...

Отзывы: