Boss Solar Strip Thermal Solar Pool Heating | INSTALLATION MANUAL
13
Revision:
C
Revision Date:
18/11/2021
SERVICE AND MAINTENANCE SCHEDULE
Servicing and maintaining the system is essential for its health and longevity. The following table displays a
service and maintenance schedule that is recommended to be followed by the homeowner.
Maintenance Issue - Service Procedure
Monthly
Quarterly
Annually
TufFilta / Strainer:
Depending upon your pool usage and level
of debris, the TufFilta / Strainer will need to be checked and
cleaned regularly
✓
Leaks:
Check for leaks on a regular basis as leaks can corrode
metal roofs and gutters. Leaks should be repaired as soon as
possible.
✓
Non-Return Valve:
The non-return valve (4 see plumbing
diagrams) is a critical system component. Checked that the 6mm
hole drilled in the flap has not become blocked and that the
collectors drain fully when the pump stops.
✓
Vacuum Release Valve:
The vacuum release valve (9) is a
critical system component. It should be checked that it is
functioning correctly and that collectors drain fully when the
pump stops. The collectors and/or piping should never appear
collapsed (concave) by negative pressure.
✓
Plumbing Degradation:
Plumbing should be checked for signs
of UV and/or chemical damage. Replace as needed.
✓
Debris Accumulation:
Check that there is no build-up of debris
around pipe work or collectors, and that water has a clear path
to run down.
✓
Winterising System:
You may need to prepare your system for
winter dormancy each year.
✓
Содержание PROSOLAR
Страница 1: ......