Boss Solar Strip Thermal Solar Pool Heating | INSTALLATION MANUAL
11
Revision:
C
Revision Date:
18/11/2021
Manual System (No Pump or Digital Controller)
Involves plumbing into the filtration line and manually opening and closing a three-way valve to divert water to the
system. This system does not require a Digital Controller or Solar Pump and is the cheapest way to plump the
system. However, you have very limited control over the heating process and must remember to go out and
adjust the valve if you want the system to operate. Before proceeding with this type of installation you should
determine the capacity of your existing pool pump. The plumbing must be cut in before any other pool equipment
(e.g. chlorinator cell, heat pump, gas heater etc.).
Requires:
•
1 x Check Valve (also known as a Non-Return or One-Way Valve)
•
1 x PVC Tee
•
1 x 3-Way Manual Valve
To Install
Identify and confirm the Pool Return line that is running from the Pool Filter Switch the system off and isolate any
valve/s (if possible) to minimise water loss. Identify the best position to cut into the line to install the three-Way
Manual Valve, PVC Tee and Check Valve. Plumb as per the diagram above. Ensure all pipework is dry and clean
before attempting to glue.