background image

 

 

 HORIZONTAL  

ELECTRIC  

5 TON LOG SPLITTER 

 

 

 

 

 
 

MODEL NO.

 

ES5T20

 

Owner’s Manual

 

 

ASSEMBLY & OPERATING INSTRUCTIONS

 

 
 

 
Purchase Date___________________ Serial No.______________________ 
Dealer________________________________________________________ 

Boss Industrial, Inc.

 • 1864 High Grove Lane, Unit 116 • Naperville, IL 60540 • USA 

Phone: (800) 780-BOSS (2677) • Fax (331) 472-2976 

www.boss-industrial.com

Содержание ES5T20

Страница 1: ...ING INSTRUCTIONS Purchase Date___________________ Serial No ______________________ Dealer________________________________________________________ Boss Industrial Inc 1864 High Grove Lane Unit 116 Nape...

Страница 2: ......

Страница 3: ...ral Safety 7 Work Area 8 Operation of the Log Splitter 8 Maintenance Safety 9 Hydraulic Safety 10 Fire Prevention 10 Assembly Instructions 11 12 Pre Operation Instructions 12 Operating Instructions 13...

Страница 4: ...nt safety information may result in serious injury or death INTENDED USE NEVER use this log splitter for any purpose other than splitting wood It is designed for this use only Any other use can cause...

Страница 5: ...Page 2...

Страница 6: ...To reduce the risk of injury user must read and understand operator s manual before using this product Eye Face Ear Protection Always wear safety goggles or safety glasses with side shields earplugs a...

Страница 7: ...roduct to your nearest AUTHORIZED SERVICE CENTER for repair When servicing use only identical replacement parts WARNING To avoid serious personal injury do not attempt to use this product until you re...

Страница 8: ...d cause electrical shock resulting in serious injury GROUNDING INSTRUCTIONS In the event of a malfunction or breakdown grounding provides a path of least resistance for electric current to reduce the...

Страница 9: ...ort legs log holder 4 Machine body Oil reservoir 5 Control handle 6 115v motor 7 Motor control box 8 On Off switch 9 Electrical cable with plug 10 Oil drain bolt with dipstick 11 Vent plug 12 Handle 1...

Страница 10: ...rical shock by preventing body contact with grounded surfaces For example pipes radiators ranges refrigerator enclosures KEEP guards in place and in good working order USE the proper extension cord Ma...

Страница 11: ...s or pieces of wood on the tool while it is in operation ONLY operate your log splitter in daylight or under good artificial light ALWAYS keep the work area clean Remove split wood around your log spl...

Страница 12: ...even if you are leaving the log splitter for a short period of time NEVER operate your log splitter when it is in poor mechanical condition or in need of repair Periodically check that all nuts bolts...

Страница 13: ...r medical treatment is not administered immediately ALWAYS be sure to relieve all pressure by shutting off the motor and moving the control handle back to stop position NEVER remove the vent plug from...

Страница 14: ...please call 1 800 780 2677 for assistance WARNING If any parts are damaged or missing do not operate this tool until the missing parts are replaced Failure to do so could result in possible serious pe...

Страница 15: ...repel the air Do not move the splitter while the vent plug is loosened as the hydraulic fluid could spill out Air must flow in and out of the oil tank during operation to prevent the seals in the hydr...

Страница 16: ...you experienced problems splitting especially hard wood do not continue to push on the control handle for more than 5 seconds Release the control handle at once to avoid damage If the motor stops turn...

Страница 17: ...eat up and could damage the tool This machine can fit in most vehicles for transportation Ensure that the splitter is properly secured before the vehicle is in motion Ensure vent plug is tightened and...

Страница 18: ...ade lubricant for the life of the unit under normal operating conditions Therefore no further lubrication is required on the bearings REPLACING HYDRAULIC OIL See FIGURES 6 7 8 9 The hydraulic oil in t...

Страница 19: ...Page 16 FIGURE 6 Drain Oil from Reservoir FIGURE 7 Note Acceptable Oil Fill Level FIGURE 8 Place Log Splitter In Vertical Position FIGURE 9 Remove U Joint and Refill Oil to Desired Level...

Страница 20: ...harpening The Wedge in the Maintenance section Locate leak s Contact the dealer Contact the dealer Log ram jerks vibrates or does not move Unit is not placed on level ground Lack of hydraulic oil Exce...

Страница 21: ...AWG 2 08mm Max splitting force 5 ton Max splitting length 20 5 in Max splitting diameter 10 in Hydraulic pressure 3000 PSI Cylinder bore 2 2 in Cycle time Feed 9 sec Retract 5 sec Max cylinder stroke...

Страница 22: ...Page 19 EXPLODED DIAGRAM PARTS LIST...

Страница 23: ...irt Proof Ring 1 22 540 853 Front Reservoir Cover 1 23 730 094 O Seal Ring 6 1 1 24 540 537 Vent Plug M4 10 1 25 750 158 Copper Seal Washer M14 1 1 26 540 333 Oil Dipstick w Oil Drain Bolt 1 27 520 97...

Страница 24: ...930 511 Cable Bushing 1 69 930 182 Power Cable STJW 3 C 14AWG 2 08 1600 1 70 740 526 Cross Recess Pan Head Screw M8 55 4 71 320 812 Front Leg 2 72 750 638 Flat Washer M8 1 4 73 750 834 Spring Washer...

Страница 25: ...or to any product that has been altered or modified The warranty does not extend to repairs made necessary by normal wear or by the use of parts or accessories which are either incompatible with the...

Страница 26: ...Page 23 1 Log Splitter 1 Owner s Manual 1 Copper Seal for Oil Drain Bolt 1 Hex Wrench PACKING LIST...

Страница 27: ...Page 24...

Страница 28: ...Page 25 Boss Industrial Inc 1864 High Grove Lane Unit 116 Naperville IL 60540 USA Phone 800 780 BOSS 2677 Fax 331 472 2976 www boss industrial com...

Отзывы: