Specifications

Frequency response 

80Hz – 16kHz with active equalization

Distortion

 

<1% @ 10% rated power input

Driver

 

Single, 4.5" (11.4 cm) Helical Voice Coil

Enclosure

 

Dual port, bass reflex type

Volume

 

200 in

3

Port resonance 

80Hz

Dispersion

 

Avg. 1kHz to 4kHz, 6dB down point: 132º

On axis directivity (Q) 

Avg. 1kHz to 4 kHz: 5

Temperature

 

Minimum: -30ºC 
Maximum: 60ºC

Weight

 

5 lb (2.3 kg)

Dimensions

11.75" (30 cm) dia. x 3.75" (9.5 cm) depth 
Grille diameter: 12" (31 cm)

Packaging Configuration

4 per carton, without grilles. Grilles may be 
purchased separately in singles or 8 per carton.

General Description

The BOSE

®

 102

®

F commercial loudspeaker is engineered for true high-

fidelity performance as part of a distributed sound system. 
It incorporates a BOSE

®

 4.5-inch (11.4 cm) HVC (Helical Voice Coil) full-

range driver in a dual-ported enclosure.

The 102

®

 flush-mount speaker can be installed in ceilings and standard 

studded walls. The actively equalized models require use of their active 
equalization curve available in select Bose electronics, and feature a 
factory installed line transformer with 2, 4, 8, 16, and 25 Watt taps. 
The front panel of this version contains a level tap switch that is easy to 
adjust with a screwdriver.

The 102

®

 loudspeaker has a polyvinyl-chloride injection-molded 

enclosure and baffle. This provides a high level of reliability and 
ruggedness. Grille and mounting accessories are available.

Sensitivity

1

 specifications  

Actively 

Equalized

Passively 

Equalized

Speech

2

89

83

Music

3

86

85

Safety Standards

The BOSE

®

 102

®

 flush-mount speaker is UL listed under UL standard 

1480, complies with ANSI/EIA-636, and when properly installed 
complies with NFPA-70 (NEC). The speaker has a flammability rating  
of 94-5V. Suitable for use indoors in damp locations. Suitable for use in 
air handling plenum spaces when used with a backcan.

Electrical Connections

1.  Loosen the wiring-well rear cover screws; swing the cover to one side.
2.  Route the source wires through the appropriate entryway and secure 

with the supplied strain relief.

3.  Using the supplied wire nuts, connect the positive source wire to the 

speaker’s black lead.

4.  Fit the leads into the portion of the well where the speaker leads 

emerge (not where the transformer and switch are located).

5. Reseat the wiring-well cover; tighten the cover screws.

BOSE

®

 

Professional Systems Division

TECHNICAL DATA SHEET

1

of 2

1  Sensitivity is measured according to the standard established by the International Electrotechnical Commission 

(IEC Publication #268-5, Sound System Equipment, Part 5: Loudspeakers, page 31). Special random noise spectra used other than pink noise are described below.

2  Speech sensitivity is measured using pink noise shaped to an average speech spectrum as defined by the InternationalElectrotechnical Commission (IEC Publication #268-16,  

Sound System Equipment, Part 16: The objective rating of speechintelligibility in auditoria by the “RASTI” method, page 19).

3  Music sensitivity is measured using pink noise shaped to an average music spectrum as defined by the International Electrotechnical Commission (IEC Publication #268-5,  

Sound System Equipment, Part 5: Loudspeakers, page 53).