Installation and connection
18
Total pressure loss values
Installation option
Notes
■
Route the exhaust air duct in such a
way that the dryer cannot draw the
moist, warm exhaust air back again.
■
The outlet for the exhaust air must
be designed or positioned in such a
way as to prevent any additional
backpressure (e.g. from a direct
ingress of wind) in the escaping
exhaust air, e.g. by using 90°, facing
down
■
The outlet for the exhaust air duct
must be no more than 2.5 m higher
than the exhaust air opening on the
appliance.
Installation options for the exhaust air
duct:
■
Through a wall box into the open
air
Example: pipe connection - inside
diameter = 100 mm, smooth
Total pressure loss
Pipe connection
0 - 50
100
0 - 80
110
120
130
A = straight piece (1.0 m)
4
B = curved pipe (R = 200 mm) 4
C = straight piece (1.5 m)
6
D = pipe elbow
19
E = telescopic wall box with grid 14
Total pressure loss
47