48
ELECTRICAL CONNECTIONS (FOR ENGINEERS ONLY)
6 720 644 593 (2010/04)
5.5.10 Configuration diagram 2-CD p-v-v - heating boost system with swimming pool with two
cylinders connected via valves, and external heat exchanger
Fig. 39
R1
Pump SP, solar circulation system
R2
Pump PD, heat exchanger
R3
Valve DWUD, anti-icing system (option)
R4
Valve DWUC for cylinder 1 selection
R5
Valve DWU3 for cylinder 2 selection
S1
Temperature sensor (T1), collector FSK
S2
Solar cylinder bottom temperature sensor (T2)
S3
Cylinder C bottom temperature sensor (TC)
S4
Solar cylinder top temperature sensor (option)
S5
Swimming pool temperature sensor
S6
Temperature sensor (TD), external heat exchanger
S7
Flow heat meter WMZ temperature sensor (option)
S8
Return heat meter WMZ temperature sensor (option)
WMZ
Heat meter (option)
WMZ
5
R1
S3
S5
S8
S7
R5
S1
R4
R2
S6
S4
R3
7747006072-28.1 SD
S2
S1 S2 S3 S4 S5 S6 S7 S8
I9
L
N
R1 N1 R2 N2 R3 R3 R4 R4 R5 R5
L3 N3 L4 N4 L5 N5
230V
AC
R4
R3
R5
R2
R1
S1 S2 S3 S4 S5 S6 S7 S8 WMZ