SERVICE AND SPARES
6 720 821 670 (2018/06)
44
COMPONENT ACCESS
Removing outer case
1. Undo and remove two screws securing appliance casing at the top of
the appliance.
2. Undo but do not remove the two screws securing appliance casing at
the bottom of the appliance.
▶ Pull case forward and remove.
Fig. 48 Remove outer case
LOWERING THE APPLIANCE CONTROLS TO THE SERVICE
POSITION:
1. Remove two screws securing the control.
2. Pull the control forward.
3. Lower the control to align the slots at the top of the control with the
lugs on the appliance framework.
4. Hang control on two lugs on appliance framework.
Fig. 49 Control panel into service position
7.2
CHECKING GAS INLET PRESSURE
Refer to section 6.5.1 for checking the gas inlet pressure
6720644744-35.1W
o
1.
2.
NOTICE:
▶ Do not continue with the other checks if the correct
gas inlet pressure can not be achieved.
6720644744-36.1Wo
1.
1.
2.
3.
4.
4.
Содержание Worcester GREENSTAR 12Ri ErP +
Страница 63: ...6 720 821 670 2018 06 63 Notes ...
Страница 64: ...6 720 821 670 2018 06 64 Notes ...
Страница 65: ...6 720 821 670 2018 06 65 Notes ...