Bosch Worcester 2000 GC2000iW 25 C Скачать руководство пользователя страница 8

Operating the appliance

 

Worcester 2000 – 6 721 814 552 (2019/09)

8

4

Operating the appliance

These operating instructions describe the operation of the gas-fired 
condensing boiler. Depending on which user interface is used the 
operation of several functions may not correspond to this description. 
Therefore please also observe the operating instructions for the user 
interface.

4.1

Switching on/off the appliance

Switching on

After initial power-up of the appliance, the appliance will initiate siphon 
fill mode.

When 

 and the flow temperature appear alternately on the display, 

the appliance remains at minimum heat output for 15 minutes to fill the 
condensate trap in the device.

Switching off

NOTICE: 

Risk of damage to the system from frost!

The heating system can freeze up after a prolonged period (e.g. during a 
power failure, switching off the power supply, faulty fuel supply, 
appliance fault etc.).

▶ Ensure that the heating system is in constant use (particularly when 

there is a risk of frost).

Frost protection for the heating system is only ensured if the heating 
pump is operational and is pumping heating water through the entire 
system.

▶ Leave the heating switched on.
▶ Set the time control to constant ON and set the room thermostat to 

12 °C.

The anti-seizing function is not active when the appliance is switched off.

The anti-seizing function prevents the heating pump and the diverter 
valve from seizing up following long periods of inactivity.

4.2

Control panel overview

Fig. 5  

[1]

Display

[2]

(

key: Heating mode on/off, set the maximum flow temperature

[3]

*

 key: Hot water mode, adjusting the hot water temperature

[4]

eco

 key: Toggle economy mode (pre-heat off)

[5]

ok

 key: Save settings

[6]

"

 key: Return/back

[7]

 key: To navigate through menus and decrease settings

[8]

 key: To navigate through menus and increase settings

[9]

Pressure gauge

0010029487-001

1

2

3

4

5

6

7

8

9

Содержание Worcester 2000 GC2000iW 25 C

Страница 1: ...6 721 814 552 2019 09 UK IE User Instructions Gas fired condensing combi appliance Worcester 2000 2 1 3 4 0 bar GC2000iW C ...

Страница 2: ...re of exceptional quality and proven reliability Our products employ the latest technologies and they are reliable extremely energy efficient offering you economical running costs and value for money They are amongst the top energy rated appliances available There is also the reassurance of our parts and labour guarantee Our Customer Service team is here to help you get the best from your Worceste...

Страница 3: ...Information 5 2 1 Appliance identification and serial number 5 2 2 Servicing 5 2 3 Maintaining your appliance 6 2 4 Benchmark standard 6 3 Prepare for operation 6 3 1 Sealed heating system 6 3 1 1 Checking the system pressure 6 3 1 2 Constantly re pressuring the system pressure 6 3 2 Topping up the system pressure 7 4 Operating the appliance 8 4 1 Switching on off the appliance 8 4 2 Control panel...

Страница 4: ...proved contractor Have any defects rectified H Danger to life from carbon monoxide Carbon monoxide CO is a poisonous gas which arisesduringtheincompletecombustionoffossilfuels such as oil gas or solid fuels Dangers arise if carbon monoxide escapes from the heating system due to a fault or a leak and collects unnoticed in enclosed spaces You can neither see taste nor smell carbon monoxide To avoid ...

Страница 5: ... similarly qualified person so that risks are avoided H Please read these instructions carefully These instructions are applicable to the Worcester appliance model s stated on the front cover only These instructions apply in the UK IE only and must be followed except for any statutory obligation 2 Product Information 2 1 Appliance identification and serial number Fig 1 Position of data label Theda...

Страница 6: ... of installation It confirms that the appliance has been installed and commissioned according to the manufacturer s instructions The service record provides space for the recording of regular servicing of the appliance heating system and this can become a valuable document when for example you wish to sell the property The service record will show a potential purchaser that the heating system has ...

Страница 7: ...pressure Turn the handles screwdriver slots back through 90 to close the valves The system fill isolation valves 6 are in a closed position the handle screwdriver slot is across the valve Top up the system pressure if as a result of the air bleeding the pressure drops off Once the pressure has settled between 1 and 1 5 bar Ensure the valves are closed Remove the hose 2 and replace the blanking cap...

Страница 8: ...failure switching off the power supply faulty fuel supply appliance fault etc Ensure that the heating system is in constant use particularly when there is a risk of frost Frost protection for the heating system is only ensured if the heating pump is operational and is pumping heating water through the entire system Leave the heating switched on Set the time control to constant ON and set the room ...

Страница 9: ...gins as soon as the DHW is being drawn In Eco mode to reduce water usage Briefly open and close the DHW tap The water is heated once to the set temperature To set ECO mode press eco until eco appears in the display To return to comfort mode press the eco key until eco vanishes from the display 4 6 Setting summer mode The heating pump and consequently the heating are switched off in summer mode The...

Страница 10: ...nce space around the appliance is restricted by objects Donotrestrictthisspacewiththeadditionofcupboards shelvesetc next to or around the appliance Do not store any combustible materials on or next to the appliance such as clothes towels paper or plastic bags Fig 7 Appliance minimum clearances Table 5 Appliance minimum clearances Description of the LED displays Example Flashing red Fault e g no co...

Страница 11: ... guarantee period Reasonable evidence of this must be supplied on request i e a completed Commissioning and service record and has been regularly serviced A call out charge will be made where The appliance is outside the guarantee period or has not been serviced in accordance with the manufacturers instructions Our Field Service Engineer finds no fault with the appliance The cause of breakdown is ...

Страница 12: ...pointments Team on 0330 123 9339 if the boiler does not restart Contact your installer in order to find a permanent solution to the problem 9 Environmental protection disposal Environmental protection is a fundamental corporate strategy of the Bosch Group Thequalityofourproducts theireconomyandenvironmentalsafetyare all of equal importance to us and all environmental protection legislation and reg...

Страница 13: ... front of the radiator should also be avoided It is advisable to manually adjust all thermostatic radiator valves every 2 3 months to prevent them sticking Ensure radiator valves are correctly set and not damaged Draughts Try to ensure that draughts around doors windows letter boxes and keyholes etc are reduced by using a suitable draught excluder WARNING Air vents Do not block or seal any air ven...

Страница 14: ...for low temperature boilers 37 C and for other heaters 50 C return temperature at heater inlet P1 kW 6 7 6 7 Useful efficiency At rated heat output and high temperature regime 1 4 87 7 87 7 At 30 of rated heat output and low temperature regime 2 1 97 9 97 9 Auxiliary electricity consumption At full load elmax kW 0 0280 0 0280 At part load elmin kW 0 0110 0 0110 In standby mode PSB kW 0 0027 0 0027...

Страница 15: ......

Страница 16: ... Kingdom Tel 0330 123 9559 worcester bosch co uk TECHNICAL SUPPORT 0330 123 3366 RENEWABLE SUPPORT 0330 123 9229 CONTROLS AND CONNECTIVITY TEAM 0330 123 3641 APPOINTMENTS 0330 123 9339 SPARES 0330 123 9779 LITERATURE 0330 123 9119 TRAINING 0330 123 0166 SALES 0330 123 9669 ...

Отзывы: