7 TECHNICAL
SPECIFICATIONS
7.1 Washer
ratings
7.1.1 WFVC electric washer ratings
120VAC, 15A, 60 Hz, 1350W (11A max.).
7.1.2 Drive motor ratings
120VAC, 3-phase, 850W (1.14 HP), 400Hz variable frequency,
asynchronous, class F insulated, with tachometer.
7.1.3 Drain pump ratings
120VAC, 60 Hz, 0.95A, 70W (3/32 HP), 16.5
Ω
, 3600 RPM, class F
insulated, 15 min. on / 45 min. off duty, thermally protected, isolated
by four rubber feet (noise/vibration dampened).
7.1.4 Drain pump flow rate
18 liters/minute @ 2.5m (8’) head and 30 liters/minute @ 1.25m (4’)
head. Pumping height 8’ (2.4 m) max.
7.1.5 Heater
ratings
120VAC, 1000W, 8.8A, 13.7 – 15.2
Ω
. Heaters can heat water up to
174ºF (79ºC), depending on cycle used.
7.1.6 Water levels (cotton cycle, empty drum)
•
Level 1:
1 – 1.6 gal. (4 – 6 l); ~ 1.7” – 2.5” (43 – 65mm)
•
Level 2 (heating):
4 – 4.5 gal. (15 – 17 l); ~ 4.5” – 5.1” (115 –
230mm)
•
Overflow:
15 gal. (57 l); ~ 10.6” – 11.4” (270 – 290mm)
7.1.7 Water inlet valve ratings
3/4” NPT threads (11.5 threads / inch), 14.5 – 145 psi pressure, 2.2
gal. (8 l) / minute – 5.2 gal (19.8 l) / minute flow rate.
702_58300000143607_ara_en_a
Page 42 of 42