en
Faults and what to do about them
40
Information on the display panel
Display
Cause/Remedy
è
■
Flashes fast + warning signal
: The door was opened and the water level is
too high. Close the door, continue the programme with
A
button or select
Spin
programme.
■
Flashes slowly
: The door lock temperature is too high to open the door.
Wait approx. 30 seconds until the door lock temperature cools down.
r
■
Flashes
(no water supply): Tap turned on? Water inlet filter blocked?
Clean the water inlet filter.
If an additional water filter has been installed (depending on the model), check
for contaminants and clean if required
~
separate installation and cleaning
instruction for water filter.
Water hose kinked or blocked?
■
Lights up
(low water pressure): For information only. This will not affect the
programme progress. The programme duration is extended.
E:18
Drain pump blocked; clean the drain pump. Clean the drainage hose on the siphon.
E:32
Alternating display with
End
when programme is finished: unbalance problem,
spinning phase is aborted.
:
■
Flashes fast
: For information only. Low line voltage is detected. The program
duration time might be extended.
■
Flashes slowly
: For information only. Low line voltage is detected during pro-
gram running. The program duration time might be extended.
Other displays
Switch off the appliance, wait for five seconds and then switch it on again.
If the display appears again, call customer services.