1 689 989 106
2012-09-10
|
Robert Bosch GmbH
Maintenance | VLS 3130 | 33
en
9. Maintenance
!
Work on electrical equipment is only to be
performed by persons with sufficient knowledge and
experience of electrical systems.
9.1
Important notes on maintenance
!
Before starting maintenance work under raised
lifting platform components, these must be secured
to prevent unintentional movement.
!
In the event of breakage of a load-bearing
component, the load-bearing structures and drive
system, including the safety devices, must be
checked to prevent falling or lowering of the load-
bearing element. Damaged parts must be replaced.
9.2 Emergency
lowering
!
Emergency lowering must only be performed by
specially trained personnel!
!
Make sure that no persons or objects are in the
danger area, and use a second person to monitor the
area!
1.
Open the front panel of the control console.
2.
Remove the screw caps on valves Y2 and Y3.
3.
Simultaneously turn the knurled nuts on Y2 and Y3 in
a counter-clockwise direction.
4.
The lifting platform lowers.
5.
After the lowering procedure, close the knurled nuts
on valves Y2 and Y3 (in a clockwise direction).
6.
Mount the screw caps on valves Y2 and Y3.
7.
Mount the front panel on to the control console.
9.3 Cleaning
!
The lifting platform safety devices are not to be
replaced or bypassed during cleaning.
!
Always raise the lifting platform when cleaning the
floor area with detergent.
9.4
Spare and wearing parts
Item/component
Order no.
Access ramp
See
spare parts list
Hydraulic fluid
20 mm elastomer retainers (x 4)
1 692 872 361
60 mm elastomer retainers (x 4)
1 692 872 362
90 mm elastomer retainers (x 4)
1 692 872 363
9.5
Maintenance by the user
The maintenance work described below must be
performed by the user.
!
Prior to maintenance, the platform must always be
disconnected from the mains and secured to prevent
unauthorized use.
!
If components are damaged or worn or do not
function properly:
Inform Bosch customer service or an authorized
service agent.
9.5.1 Maintenance
agreement
i
Regular upkeep of the lifting platform is essential to
ensure a long service life and permanent readiness
for use. We recommend concluding a maintenance
agreement with Bosch customer service or an
authorized service agent.
The lifting platform is only to be cleaned using water
containing a small quantity of neutral or slightly alkaline
detergent. The water temperature must not exceed
25 °C.
The components can be wiped with soft cloths or
sponges. Rinse components with clean water after
cleaning.
!
Never use cleaning agents which corrode paintwork,
coatings or sealing materials:
No solvents (esters, ketones, alcohols, halogenated
hydrocarbons)
No abrasive cleaning agents (scouring powder)
No acidic or highly alkaline cleaning agents
!
Never clean the lifting platform with high-pressure or
steam cleaners.
i
A
preservative agent
(e.g. commercially available
transparent cavity sealant) provides extra protection
for the coating. This should be applied in all areas
with exposed edges or where moisture may ingress.
This does not apply to the top edge of the runway.