All-pole power switch - Incorporate an all-pole listed circuit breaker, with a contact separation
of at least 20A, 3 mm (400 V not essential) in each pole, into the electrical installation of the
building.If it is needed to open the housing for servicing and/or other activities, use this all-
pole switch as the main disconnect device for switching off the voltage to the unit.
!
Warning!
For the standard models with 120/230 VAC power, an external junction box with a readily
accessible 2-pole disconnect device must be incorporated.For the IR model UPH-H-WDIR-24,
the 24 VAC power must be provided by a UL listed power supply with a double insulation
transformer.
Camera grounding - For mounting the camera in potentially damp environments, ensure to
ground the system using the ground connection of the power supply connector (see section:
Connecting external power supply).
Camera lens - An assembled camera lens in the outdoor housing must comply and be tested in
accordance with UL/IEC60950. Any output or signal lines from the camera must be SELV or
Limited Power Source. For safety reasons the environmental specification of the camera lens
assembly must be within the environmental specification of -10 °C (14 °F) to 50 °C (122 °F).
Camera signal - Protect the cable with a primary protector if the camera signal is beyond 140
feet, in accordance with NEC800 (CEC Section 60).
Coax grounding:
–
Ground the cable system if connecting an outside cable system to the unit.
–
Connect outdoor equipment to the unit's inputs only after this unit has had its grounding
plug connected to a grounded outlet or its ground terminal is properly connected to a
ground source.
–
Disconnect the unit's input connectors from outdoor equipment before disconnecting the
grounding plug or grounding terminal.
–
Follow proper safety precautions such as grounding for any outdoor device connected to
this unit.
U.S.A. models only - Section 810 of the National Electrical Code, ANSI/NFPA No.70, provides
information regarding proper grounding of the mount and supporting structure, grounding of
the coax to a discharge unit, size of grounding conductors, location of discharge unit,
connection to grounding electrodes, and requirements for the grounding electrode.
Electronic Surveillance - This device is intended for use in public areas only. U.S. federal law
strictly prohibits surreptitious recording of oral communications.
Environmental statement - Bosch has a strong commitment towards the environment. This
unit has been designed to respect the environment as much as possible.
High-Speed Positioning System
(HSPS)
Safety | en
9
Bosch Security Systems, Inc.
Operation Manual
2013.11 | 5.2 | F.01U.291.981
Содержание UPH Series
Страница 1: ...High Speed Positioning System HSPS UPH Series ...
Страница 2: ...en Operation Manual ...
Страница 80: ......
Страница 81: ......