2.6
Product data for energy consumption
The following product data satisfy the requirements of the EU
Regulations No. 811/2013 and No. 812/2013 supplementing EU
Regulation 2017/1369.
Manufacturers who implement these guidelines and state the ErP values
are permitted to use the "CE" mark.
Table 6 Product data for energy consumption
3
Regulations
Observe the following guidelines and standards:
• Local regulations
•
EnEG (Building Regulations)
(in Germany)
•
EnEV
(in Germany)
Installation of, and equipment for, heating and water heating systems:
•
DIN
and
EN
standards
–
DIN 4753-1
– Water heaters ...; requirements, identification,
equipment and testing
–
DIN 4753-3
– Water heaters ...; corrosion protection on the
water side with glass lining; requirements and testing (product
standard)
–
DIN 4753-7
– Water heaters, containers with a volume up to
1000 l, manufacturing, thermal insulation and corrosion
protection requirements
–
DIN EN 12897
– Water supply - regulation for ... DHW cylinders
(product standard)
–
DIN 1988-100
– Technical rules for potable water installations
–
DIN EN 1717
– Protection of potable water against pollution ...
–
DIN EN 806-5
– Technical rules for potable water installations
–
DIN 4708
– Central water heating systems
–
EN 12975
– Thermal solar systems and their components
(collectors)
•
DVGW
– Code of Practise W 551 – domestic hot water heating systems
and pipework; technical measures to inhibit the growth of
legionella bacteria in new systems; ...
– Code of Practise W 553 – Sizing DHW circulation systems ...
Product data for energy consumption
•
EU Regulation
and
Directives
–
EU Regulation 2017/1369
–
EU Regulation 811/2013
and
812/2013
4
Transport
WARNING
Risk of injury from carrying heavy loads and inadequately securing
loads for transport!
▶ Use suitable means of transport.
▶ Secure the cylinder to prevent it falling.
The outer casing can be removed for transportation (
If there is limited space for access, a slat can be left screwed on and used
to carry the cylinder to the required location, where it is then removed
(
▶ Move packed cylinder with a sack truck and lashing strap
(
Fig. 9, page 69).
-or-
▶ Move unpacked cylinder with a transport net (accessory);
during handling, protect connections against possible damage
(
Fig. 9, page 69).
The heat exchanger is not mounted completely rigidly. Rattling noises
may therefore be heard during transportation. This is harmless from a
technical standpoint and is not a sign that the cylinder is faulty.
Product
number
Product
type
Cylinder
volume (V)
Heat
retention
loss (S)
Energy
efficiency
class for
DHW
treatment
7735501559
WS 290-5
EPK1 C
290,0 l
93,0 W
C
7735501558
WS 300-5
PK1 C
290,0 l
80,0 W
C
7735501560
WS 400-5
EPK1 C
371,1 l
100,0 W
C
8732935224
WS 400-5
EKP1 B
367,0 l
73,8 W
B
7735501561
W 300-5
PK1 B
294,0 l
74,9 W
C
7735501562
W 400-5
PK1 C
375,0 l
93,1 W
C
8732935226
W 400-5
KP1 B
375,0 l
69,9 W
B
Содержание Stora W 300-5 PK
Страница 70: ...Stora 6720821526 2021 06 70 10 11 0010032870 001 0010032872 001 12 13 0010032874 001 1 2 0010002859 001 1 2 3 ...
Страница 71: ...71 Stora 6720821526 2021 06 14 15 0010032883 001 0010033017 001 16 ...
Страница 73: ...73 Stora 6720821526 2021 06 19 20 1 2 0010009754 001 0010032885 001 21 22 0010032886 001 2 1 2 0010032887 001 ...
Страница 75: ...75 Stora 6720821526 2021 06 27 28 29 30 ...
Страница 77: ...77 Stora 6720821526 2021 06 34 35 0010032899 001 1 1 2 3 0010032900 001 ...
Страница 78: ......
Страница 79: ......
Страница 80: ...Bosch Thermotechnik GmbH Junkersstrasse 20 24 D 73249 Wernau www bosch thermotechnology com ...