1 695 600 539
2016-07-22
|
28 | Start Line WBE 260 | Initial commissioning
en
4.4
Power socket
!
WBE 260 must not be connected to the power
supply unless its voltage is the same same as that
specified on the rating plate.
1. Check to ensure that power supply is at the same
voltage as specified on the rating plate.
2.
Check the usual standard for machines and ensure
that the power connector and power port on cus-
tomer premises both comply with that standard.
3.
Connect up to power supply.
4.
Connect switch connector of wheel-guard cover.
Fig. 8:
Connect switch connector of wheel-guard cover
2.
Attaching the wheel-guard hood and hood bracket.
Fig. 6:
Fitting the wheel-guard hood
3.
Install wheel-guard hood in support and tighten the
screw.
4.
Install support bracket 2, then install the plate as
shown in the following Figure.
Fig. 7:
Installing the support bracket
4.5
Checking direction of rotation
1.
Check whether the WBE 260 is properly connected
to the mains.
2.
Switch on the WBE 260 at the on/off switch.
3.
Close the wheel-guard hood.
Flange shaft rotates.
!
If flange shaft does not rotate, press button <???>.
i
If the direction of rotation is incorrect the WBE 260
comes to an immediate halt and the error message
ERR 3
is displayed.
4. Check direction of rotation of flange shaft.
i
The correct direction of rotation is indicated by a label
on the right side of the WBE 260.
4.6
WBE 260 calibration
!
Calibration must be performed after initial commis-
sioning.
1. Calibrate the flange.
2.
Calibrate rim-distance gage.
3.
Calibrate WBE 260.
4.
Perform reference measurement.
i
The calibration is described in the section "Calibra-
tion".