Trouble Condition
Description
Power Missing
The system has detected that the AC mains supply has failed or is disconnected on the control panel.
If there is not a general power outage in your area then you should contact your security company.
AC Missing
The system has detected that the AC mains supply has failed or is disconnected on a power supply
module. If there is not a general power outage in your area then you should contact your security
company.
Battery Low
The backup battery has failed the periodic test which the system performs on a regular basis. You
should contact your security company as the battery may need replacing.
Battery Missing
The system has detected that its backup battery has been disconnected.
Low Battery
The system has detected that an RF sensor has a low battery condition. You should contact your
security company as the battery may need replacing.
Box Tamper
The system has detected that the tamper circuit on a power supply module is faulted.
Temperature Alert
The system has detected that the keypad temperature has exceeded the global temperature high
and/or temperature low settings.
Receiver Missing
The system has detected that the RF receiver is disconnected.
Case Tamper
The system has detected that the tamper circuit on the RF receiver is faulted.
Receiver Jam
The system has registered a jamming fault from the RF receiver. This situation may preven certain
parts of your system from working correctly. You should contact your security company.
Comms Fail Route1
The system has failed to send reports to the primary report contact. You should contact your security
company.
Comms Fail Route 2
The system has failed to send reports to the secondary report contact.
You should contact your security company.
Sensor Watch Alert
The control panel has detected a zone has failed to detect a change of state within the sensor watch
period set by the installer.
Comms BUSS Trble
The system has failed to communicate to a system device (e.g. keypad etc).
Default PIN Trble
The system has detected that either the Installer PIN or User 1 PIN has not been changed from the
factory default codes. These codes should be changed immediately to prevent a security risk.
Date & Time
The system date and time needs to be set.
Cabinet Tamper
The system has detected that someone has tampered with its metal enclosure or that it has been
forced open. Inspect and contact your security company if necessary.
Connection Trouble
The system has detected that an output device (eg. external siren) has failed or has been
disconnected from the system.
Overload Condition
The system has detected that an output has an over current condition.
Zone Was In Alarm
A zone was previously in alarm and requires alarm memory reset to clear. Turn the area on and then
off again to clear alarm memory.
Telco Line Fail
The system has detected that its telephone line has been disconnected for a minimum of 30 seconds.
LAN+ Overload
The system has detected that the current load has exceeded the maximum LAN rating.
You should contact your security company.
COMM+ Overload
The system has detected that the current load has exceeded it’s maximum COMM+ rating.
You should contact your security company.
ACC+ Overload
The system has detected that the current load has exceeded it’s maximum ACCS+ rating.
You should contact your security company.
Service Required
The system displays this trouble condition to remind you that a service call is due.
Memory Checksum
The system has detected an error with its internal memory.
You should contact your security company.
Phone Line In Use
The system is using the phone line.
Battery Trouble
The system has detected that the Real Time Clock Module backup battery voltage is low or missing
Table 8: Control Panel Trouble Messages