Location 267 to 378
Location
Default
Zone Options 2
362
14
Zone Report Options
364
1
Zone #15 (Default = Not used)
Zone Type
365
15
Zone Pulse Count
366
0
Zone Pulse Count Time
367
0
Zone Options 1
368
1
Zone Options 2
369
14
Zone Report Options
371
1
Zone #16 (Default = Not used)
Zone Type
372
15
Zone Pulse Count
373
0
Zone Pulse Count Time
374
0
Zone Options 1
375
1
Zone Options 2
376
14
Zone Report Options
378
1
The Solution 2000 control panel supports up to 8 zones. The Solution 3000 control panel
supports up to 16 zones. Zone 9-16 can only be used in Solution 3000 control panels when the
EOL Resistor Value is set as 14 or 15.
Zone Types
The zone types are listed in the table below.
Zone Type
Description
0
Instant
1
Handover
2
Delay-1
3
Delay-2
4
Reserved
5
Reserved
6
24-Hour Medical
7
24-Hour Panic
8
24-Hour Holdup
9
24-Hour Tamper
13.3.2
Control Panel
Zone Information | en
97
Bosch Security Systems, Inc.
Installation Guide
2017.10 | 03 | F.01U.298.026
Содержание Solution 2000
Страница 1: ...Control Panel Solution 2000 3000 en Installation Guide ...
Страница 2: ......
Страница 10: ...10 en Introduction Control Panel 2017 10 03 F 01U 298 026 Installation Guide Bosch Security Systems Inc ...
Страница 149: ......
Страница 150: ......