To program the telco arming sequence:
1.
Enter your passcode and press [3][AWAY]. Three beeps sound and the STAY and AWAY
indicators flash.
2.
Press [1][AWAY] to change the telco arming sequence. Three beeps sound.
–
If a call forward sequence is already programmed, the sequence is displayed one digit at
a time using the codepad indicators. Refer to the table Telco Arm/Disarm Digits above for
the indicators and their meanings.
–
If no call forward sequence is programmed, an additional two beeps sound after entering
this mode. These two beeps normally sound after the last digit of the call forward
sequence is displayed.
3.
Enter the desired call forward sequence. For example, program [* 6 1][phone number][#]
for the call forward – no answer sequence, or [* 2 1][phone number][#] for the call
forward – immediate sequence.
Notice!
When you program a * in the telco arm sequence, enter [STAY][1]. When you program the # in
the telco arm sequence, enter [STAY][2].
4.
Press [STAY][2][AWAY]. Two beeps sound and the system returns to the disarmed state.
Example
If you want to automatically divert all unanswered incoming calls to another telephone number
(for example, 9672 1777) when the system is armed in AWAY Mode, enter:
[1234 3][AWAY][1][AWAY][STAY]
[1 6 1 9 6 7 2 1 7 7 7][STAY][2][AWAY]
You can suspend the telco arming sequence at any time. To disable the telco arming
sequence:
Enter your passcode and press [3][AWAY][1] [AWAY][STAY][5][AWAY].
To program the telco disarming sequence:
1.
Enter your passcode and press [3][AWAY]. Three beeps sound and the STAY and AWAY
indicators flash.
2.
Press [2][AWAY] to change the telco disarming sequence. Three beeps sound.
If a telco disarming sequence is already programmed, the sequence is displayed one digit
at a time using the codepad indicators. Refer to the Telco Arm/Disarm Dialing Digits table
above for the indicators and their meanings.
If no telco disarming sequence is programmed, an additional two beeps sound after
entering this mode. These two beeps normally sound after the last digit of the sequence
is displayed.
3.
Enter the desired call forward disable sequence. For example, program [# 6 1 #] to
disable the call forward – no answer sequence, or [# 2 1 #] to disable the call forward –
immediate sequence.
4.
Press [AWAY]. Two beeps sound and the system returns to the disarmed state.
You can suspend the telco disarming sequence at any time. To disable the telco disarming
sequence:
Enter your Installer Code and press [3][AWAY][2] [AWAY][STAY][5][AWAY].
Setting STAY Mode 2 Bypass Zones
This function allows the installer to select the zones that are automatically isolated when the
system is armed in STAY Mode 2.
To arm the system in STAY Mode 2, press and hold [0] until two beeps sound. Refer to Arming
the system from STAY Mode 2, page 33 for more information.
7.1.7
Control Panel
System Functions | en
47
Bosch Security Systems, Inc.
Installation Guide
2017.10 | 03 | F.01U.298.026
Содержание Solution 2000
Страница 1: ...Control Panel Solution 2000 3000 en Installation Guide ...
Страница 2: ......
Страница 10: ...10 en Introduction Control Panel 2017 10 03 F 01U 298 026 Installation Guide Bosch Security Systems Inc ...
Страница 149: ......
Страница 150: ......