Bosch Security Systems 09/07 BLCC500R FTR1.02
Quick Start Guide
Copyright © 2007
E&OE
Inputs > Tamper Inputs >
Tamper Options
MENU 3-6-0
1
Display Panel Tamper
Y
2
Report Panel Tamper
Y
3
Audible Panel Tamper
Y
4
Display Expander Tamper
Y
5
Report Expander Tamper
Y
6
Audible Expander Tamper
Y
7
Reserved
N
8
Reserved
N
This location is a Bit option field. Press Keys [1] – [8] to turn ON and
OFF the required options. The option is selected or ON when the
coresponding zone indicator is on. Press [OK] To Save when finished.
Inputs > Input Testing >
Walk Test All Zones
MENU 3-9-0
Walk Test A Zones
MENU 3-9-1
Inputs > Input Testing >
Sensor Watch Time
MENU 3-9-2
0 3 0
(*** System Wide Parameter ***)
DAYS
Enter 0 – 255 + [OK] To Program The Sensor Watch Time In Days
(0 = Disabled)
Output Programming
Outputs > Commands >
Output Status
MENU 4-0-0
Turn Output On/Off
MENU 4-0-1
Outputs > Properties >
Output Name
MENU 4-1-0
O u
t
p u
t
1
N a m e
Use [
] and [
] Keys To Scroll the Cursor Left and Right. Use Keys [0]
– [9] + [
] and [
] To Select Characters. When finished press [OK] To
Save. Press [OFF] To Clear From The Current Cursor Position.
Outputs > Properties >
Event Type
MENU 4-1-1
0 0 0
Enter desired Event type 0 – 255 + [OK].
See Output Event Type table for available options.
Outputs > Properties >
Event Assignment
MENU 4-1-2
0 0 1
Enter 0 to 255 to program the Area, User, Zone, Keypad or Access
Group Number You Want The Output To Follow Then Press [OK].
(0 = Unrestricted all Areas, Users, Zones etc)
Output Default Table
��� ����� ����� ���� ��� ������� ������ ��� ��� ������ ���������� �� ��� �������� ���� ������� � �� � ��� ���� �������
������� �������� ������� � �� � ��� ���� ��������� �� ��� �������� ������ ����� �������� ������ �������� ��� fi�����
������� ������ ��� � ��� �����������
����������� ������
������ �
������ �
������ �
������ �
������ �
������ �
������ �
������ �
Output Name
External
Siren
Strobe
Light
Smoke
Sensor PWR
Internal
Siren
Output 5
Name
Output 6
Name
Output 7
Name
Output 8
Name
Event Type
36
(External
Siren)
48
(Strobe)
49
(Smoke
Sensor GND)
37
(Internal
Siren)
0
0
0
0
Event Assignment
1
1
1
1
1
1
1
1
Output Polarity
14
6
11
6
0
0
0
0
Time Parameter
N° Of Hours
000
008
000
000
000
000
000
000
N° Of Minutes
005
000
000
005
000
000
000
000
N° Of Seconds
000
000
010
000
000
000
000
000
N° Of 1/10 Seconds
000
000
000
000
000
000
000
000
Output Options
Do not Operate If Low Battery
Y
Y
Y
Y
N
N
N
N
Display Output Overload
Y
Y
Y
Y
N/A
N/A
N/A
N/A
Report Output Overload
Y
Y
Y
Y
N/A
N/A
N/A
N/A
Display Missing Output
Device
Y
N
N
N
N/A
N/A
N/A
N/A
Report Missing Output Device
Y
N
N
N
N/A
N/A
N/A
N/A
Alarm On Device Fail
N
N
N
N
N/A
N/A
N/A
N/A
Block Output If Armed All On
N
N
N
N
N
N
N
N
Display Status On Keypad
N
N
N
N
N
N
N
N
Table 20: Output Default Table